Přejít k obsahu
Merck
Všechny fotografie(1)

Key Documents

30289-U

Supelco

Tedlar® PLV Gas Sampling Bag

0.6L w/Thermogreen® LB-2 Septa

Synonyma:

Tedlar® Gas Sampling Bag

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

UNSPSC Code:
41104008
NACRES:
NB.24

product name

0.6L Tedlar® PLV Gas Sampling Bag w/Thermogreen® LB-2 Septa,

material

Tedlar® PVDF film

Quality Level

agency

suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC)
suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC)
suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs))
suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC))
suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS)
suitable for NIOSH 3704 (Perchloroethylene)

description

Push/Pull Lock Valve (PLV)
septum type: yes; Thermogreen® LB-2

packaging

pkg of 10 bags

technique(s)

whole air sampling: suitable

maximum volume × W × L

0.6 L × 6 in. × 6 in.

application(s)

air monitoring
environmental
industrial hygiene

compatibility

for use with Calibration mixes - gas phase standards/gas mixtures

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

General description

Tedlar is recommended in several US EPA methods for sampling VOCs and sulfur compounds. Our Tedlar is made from a high-quality 2 mil Tedlar film for superior inertness, impermeability, sample integrity and good recovery data. Our Push Lock Valve (PLV) and seam-sealing process ensure that these bags are sturdy and virtually leak-proof, even under the most demanding sampling and shipping conditions.

Application


  • The Effect of Tedlar Bags on the Composition of Exhaled Human Breath Samples: This study investigates the impact of using Tedlar® gas sampling bags on the composition of exhaled breath samples, crucial for accurate health diagnostics and environmental monitoring (Zhao, Zhu, Zhang, 2022).

  • Quantification of volatile organic compounds by secondary electrospray ionization-high resolution mass spectrometry: Research discusses the efficiency of Tedlar® bags in capturing and preserving volatile organic compounds for high-resolution mass spectrometry analysis, vital for chemical and environmental analysis (Liu, Zeng, Sinues, Fang, Zhou, Li, 2021).

  • Washout kinetics of ethanol from the airways following inhalation of ethanol vapors and use of mouthwash: The study utilizes Tedlar® bags to evaluate the washout kinetics of ethanol, providing insights into occupational health and forensic medicine (Ernstgård, Pexaras, Johanson, 2020).

  • Testing odorants recovery from a novel metallized fluorinated ethylene propylene gas sampling bag: This investigation compares the effectiveness of Tedlar® bags in recovering odorants, essential for environmental odor management (Zhu, Koziel, Cai, Wright, Kuhrt, 2015).

  • Stability of selected volatile breath constituents in Tedlar, Kynar and Flexfilm sampling bags: Analyzes the stability of volatile compounds in Tedlar® bags, crucial for ensuring the reliability of breath analysis in clinical diagnostics and environmental studies (Mochalski, King, Unterkofler, Amann, 2013).

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Tedlar is a registered trademark of E. I. du Pont de Nemours and Company
Thermogreen is a registered trademark of Merck KGaA, Darmstadt, Germany

Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

Je nám líto, ale pro tento produkt momentálně nemáme COA k dispozici online.

Potřebujete-li pomoc, obraťte se na Zákaznická podpora

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Alfredo Córdova Lizama et al.
Bioresource technology, 275, 352-359 (2019-01-01)
This work studied the effects on the anaerobic digestion of sewage sludge by zero valent iron nanoparticles (NZVI) dosage. Biochemical methane potential tests were carried out with 5-9 mg/gVS (99.7%, 40-60 nm). The biogas yield increased from 132 (control) to 310 mL/gVS with

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..