34036
Aflatoxin Mix 4 solution
analytical standard
About This Item
Doporučené produkty
grade
analytical standard
shelf life
limited shelf life, expiry date on the label
concentration
0.5 μg/mL B2 and G2 in acetonitrile
2 μg/mL B1 and G1 in acetonitrile
technique(s)
HPLC: suitable
gas chromatography (GC): suitable
application(s)
cleaning products
cosmetics
food and beverages
personal care
format
multi-component solution
storage temp.
−20°C
Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů
Související kategorie
General description
Application
This aflatoxin mix 4 solution was used as follows:
- Ultra-high-performance liquid chromatography-fluorescence detection (UHPLC-FLD) based quantification of aflatoxins— B1, B2, G1, and G2, in the coffee bean and powder samples
- Estimation of aflatoxins (B1, B2, G1, and G2) in samples of maize, rice, sorghum meal, and peanuts by ultra high-performance liquid chromatography coupled with a fluorescence detector
- Determination of naturally occurring aflatoxins in 65 peanut-enriched flour samples by high-performance liquid chromatography (HPLC) combined with fluorescence detection
Other Notes
signalword
Danger
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Storage Class
3 - Flammable liquids
wgk_germany
WGK 2
flash_point_f
35.6 °F - closed cup
flash_point_c
2 °C - closed cup
ppe
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Vyberte jednu z posledních verzí:
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Sortimentní položky
Supel Tox AflaZea SPE improves analyte recovery with less sample volume, while HPLC confirms effective elimination of interferences.
Analyte recovery values from spiked cannabis extracts ranged from 102 to 127% with RSD below 12% for 3 replicates. Excellent recovery values were even observed for Aflatoxins B2 and G2 which were spiked at a low level of 6.1 ppb.
Cannabis testing regulations include analysis of purity, potency, and contaminants. Learn more about analysis of cannabis for pesticides, mycotoxins, and pyrethrins registered in California by LC-MS/MS and GC-MS/MS Using Ascentis® Express Biphenyl and SLB®-5ms Columns
Protokoly
solution, 2 μg/mL in acetonitrile, analytical standard
Související obsah
Detailed list of mycotoxin analysis products for Food & Beverage manufacturers and testers, ensuring safety standards.
Chromatograms
application for HPLCapplication for HPLCNáš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.