The following protocol is recommended:
1. Before opening the vial, spin down the solid to the bottom by a
microcentrifuge or by a desktop centrifuge.
2. Warm the vial to room temperature and add DMSO to prepare a
1000X stock solution of 1-5 mM (freeze aliquots at -20°C).
3. Dilute in cell culture media at a final concentration of 1-5 µM and add
to cells in culture. Incubate at 37°C for 20-45 minutes.
4. Wash cells with PBS buffer before imaging.
Vybrat velikost
9 880,00 Kč
9 880,00 Kč
Odhaduje se, že bude odesláno dnespodrobné informace
O této položce
Přeskočit na
Název produktu
BioTracker Cystine-FITC Live Cell Dye, Live cell imaging dye that measures cystine uptake at the single cell level used to detect glutathione (GSH) synthesis, reactive oxygen species (ROS) detoxification, T-cell activation and B-cell development.
assay
≥98% (H-NMR)
≥98% (HPLC)
≥98% (LC/MS)
≥98% (elemental analysis)
technique(s)
cell based assay: suitable
detection method
fluorometric
shipped in
ambient
1 of 4
Tato položka | SCT046 | SCT044 | SCT036 |
|---|---|---|---|
| technique(s) cell based assay: suitable | technique(s) cell based assay: suitable | technique(s) cell based assay: suitable | technique(s) cell based assay: suitable |
| shipped in ambient | shipped in ambient | shipped in ambient | shipped in ambient |
| assay ≥98% (H-NMR), ≥98% (LC/MS), ≥98% (HPLC), ≥98% (elemental analysis) | assay ≥98% (H-NMR), ≥98% (HPLC), ≥98% (LC/MS), ≥98% (elemental analysis) | assay ≥98% (H-NMR), ≥98% (HPLC), ≥98% (LC/MS), ≥98% (elemental analysis) | assay - |
| detection method fluorometric | detection method fluorometric | detection method fluorometric | detection method fluorometric |
Analysis Note
Molar Mass: 625.65 g/mol
Application
Cell Imaging
Live Cell Dye
Disclaimer
General description
The BioTracker Cystine-FITC dye is a live cell green fluorescent imaging probe that measures cystine uptake at the single cell level. The probe has been used to measure T-cell activation using traditional and imaging flow cytometry methods.
Spectral Properties
Absorbance: 450nm
Emission: 525nm
Physical form
Preparation Note
Note: Centrifuge vial briefly to collect contents at bottom of vial before opening.
Skladovací třída
11 - Combustible Solids
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Související obsah
-
How should I dissolve the reagent when I want to add it to the cell experiment?
1 answer-
Helpful?
-
Active Filters
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis