Přejít k obsahu
Merck
Všechny fotografie(1)

Key Documents

1.05716

Supelco

TLC plates, Cellulose

pkg of 25 plates, plate L × W 20 cm × 20 cm, glass support

Synonyma:

Cellulose Thin Layer Chromatography Plates

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

UNSPSC Code:
41115711
NACRES:
NB.21

material

cellulose matrix
glass support

Quality Level

feature

binder Organic Polymer
fluorescent indicator: no

packaging

pkg of 25 plates

technique(s)

thin layer chromatography (TLC): suitable

layer thickness

80-120 μm

plate L × W

20 cm × 20 cm

storage temp.

2-30°C

General description

25 Glass plates 20 x 20 cm
Cellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid derivatives. We offer cellulose plates in two grades: TLC for conventional and HPTLC for demanding, high-performance separations.

Application


  • Rapid and sensitive naked eye detection of faecal pigments using their enhanced solid-state green fluorescence on a zinc acetate substrate.: This study highlights a rapid and sensitive method for detecting fecal pigments using cellulose TLC plates and zinc acetate substrate, which enhances green fluorescence visible to the naked eye (Prakash and Mishra, 2022).

  • Long-Term Fluorescence Behavior of CdSe/ZnS Quantum Dots on Various Planar Chromatographic Stationary Phases.: This research investigates the fluorescence behavior of quantum dots on cellulose TLC plates, providing insights into their long-term stability and potential analytical applications (Zarzycki, 2022).

  • Investigation of Hybrid Methods for Elimination of Brilliant Blue Dye from Water Phase Using Various Nanomaterials Combined with Activated Sludge and Duckweed.: This article explores the use of nanomaterials, including cellulose TLC plates, for the effective removal of dyes from water, demonstrating their utility in environmental chemistry (Zarzycki et al., 2021).

  • Low-Temperature Plasma Probe Mass Spectrometry for Analytes Separated on Thin-Layer Chromatography Plates: Direct vs Laser Assisted Desorption.: This research compares direct and laser-assisted desorption methods for analytes separated on cellulose TLC plates, highlighting advancements in mass spectrometry techniques (Gong et al., 2020).

Linkage

Replaces: 5716-7; 5716

Analysis Note

Layer thickness: 80 - 120 µm
Deviation of layer thickness per plate: ≤ 30 µm
Aminoacid test
hRf-values
- L-serine, amino acid test:
20 - 30
- L-threonine, amino acid test: 29 - 36
- L-alanine, amino acid test: 30 - 40
- L-methionine, amino acid test: 49 - 60
- L-phenylalanine, amino acid test: 59 - 70
- L-leucine, amino acid test: 66 - 76
Typical value determined on a plate
Eluent: 1-Butanol/ acetone/ acetic acid/ water (35/35/7/23 v/v/v/v) twice developed

Storage Class

10-13 - German Storage Class 10 to 13


Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.