03-0185-00
SMC® Human Total Tau High Sensitivity Immunoassay Kit
Synonyma:
Microtubile-associated protein tau immunoassay kit, Neurofibrillary tangle protein immunoassay kit, Tau Single Molecule Counting Kit, Tau ultra-sensitive immunoassay
About This Item
Doporučené produkty
species reactivity
human
manufacturer/tradename
SMC®
assay range
sensitivity: 4.69 pg/mL
((lower limit of quantification))
inter-assay cv: ≤4%
intra-assay cv: ≤8%
(Intra-assay CV n=5; Inter-assay n=3)
Související kategorie
General description
The SMC® Human Total Tau High Sensitivity Immunoassay Kit contains all reagents required to perform the assay. This assay takes advantage of a standard immunoassay workflow configured in a standard plate format. Assay protocols are similar to existing sandwich ELISA methods with two key differences:
1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification.
2) The Erenna and TM="SMCxPRO"] immunoassay systems detect analytes using Single Molecule Counting SMC® technology.
Specificity
- Non Human Primate – 50%
- Mouse – 100%
- Rat – 100%
- Canine – 100%
- Feline – 75%
Application
This new streamline kit has the following features:
- Improved options for sample prep and incubation
- Lyophilization protein standard for uniform shipping and storage condition
- Increased reagent volumes to accommodate automation
- Able to achieve assay specifications on both SMCxPRO® and Erenna.
Research Category:
Neuroscience
neurological
Research Sub-Category:
Alzheimer′s Disease
Aging, Nervous System
Neurodegenerative Diseases
Neurofilament & Neuron Metabolism
Neuronal & Glial Markers
Neuroregenerative Medicine
Neuroscience
Components
- Assay Buffer
- Total Tau Coated Beads
- Standard Diluent
- Total Tau Detection Antibody
- Total Tau Standard
- 10X Wash Buffer
- Buffer D
- Elution Buffer B
Specifications
Minimum of 4 plasma samples spiked with average recovery of 82% with a range of 76-88%
Minimum of 5 CSF samples spiked with average recovery of 91% with a range of 85-106%
Legal Information
Disclaimer
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B - STOT RE 2 Inhalation
target_organs
Respiratory Tract
Storage Class
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Související obsah
Neuroscience biomarker research expands with high-sensitivity immunoassays for low-abundant biomarkers.
Explore high-sensitivity SMC® neurology immunoassays that precisely measure low levels of neurology protein analytes, such as NF-L or Tau proteins.
Find immunoassays to explore neuroimmunology and neuroinflammation cytokines and neurodegenerative disease biomarkers.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.