H-017
m-Hydroxybenzoylecgonine solution
1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
About This Item
Doporučené produkty
grade
certified reference material
form
liquid
feature
Snap-N-Spike®/Snap-N-Shoot®
packaging
ampule of 1 mL
manufacturer/tradename
Cerilliant®
drug control
Narcotic Licence Schedule A (Switzerland)
concentration
1.0 mg/mL in methanol
technique(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
application(s)
forensics and toxicology
format
single component solution
storage temp.
−20°C
SMILES string
CN1[C@H]2CC[C@@H]1[C@H]([C@H](C2)OC(=O)c3cccc(O)c3)C(O)=O
InChI
1S/C16H19NO5/c1-17-10-5-6-12(17)14(15(19)20)13(8-10)22-16(21)9-3-2-4-11(18)7-9/h2-4,7,10,12-14,18H,5-6,8H2,1H3,(H,19,20)/t10-,12+,13-,14+/m0/s1
InChI key
XCJJCRPRQYXLRE-AHLTXXRQSA-N
General description
Application
- m-Hydroxybenzoylecgonine as a forensic toxicology standard: A study optimized and validated a method for analyzing cocaine and several metabolites including m-Hydroxybenzoylecgonine in human urine via gas chromatography-mass spectrometry, emphasizing its utility in forensic and toxicological applications (Fernández et al., 2019).
- m-Hydroxybenzoylecgonine for stability studies in toxicology: Research assessed the stability of cocaine metabolites such as m-Hydroxybenzoylecgonine in meconium, contributing to better forensic practices by determining optimal storage conditions (Wu et al., 2017).
- Accelerated solvent extraction featuring m-Hydroxybenzoylecgonine: A protocol was developed for the extraction of cocaine and its biomarkers from meconium, utilizing m-Hydroxybenzoylecgonine to monitor drug exposure, enhancing the accuracy of drug testing in neonatal care (Mantovani et al., 2014).
Legal Information
Related product
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
target_organs
Eyes
Storage Class
3 - Flammable liquids
wgk_germany
WGK 1
flash_point_f
49.5 °F - closed cup
flash_point_c
9.7 °C - closed cup
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.