Přejít k obsahu
Merck
Všechny fotografie(1)

Key Documents

446130

Sigma-Aldrich

3-[Tris(trimethylsiloxy)silyl]propyl methacrylate

contains MEHQ + HQ as stabilizer, 98%

Synonyma:

Tris, (3-Methacryloyloxypropyl)tris(trimethylsiloxy)silane

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Lineární vzorec:
H2C=C(CH3)CO2(CH2)3Si[OSi(CH3)3]3
Číslo CAS:
Molekulová hmotnost:
422.81
Beilstein/REAXYS Number:
1888727
EC Number:
MDL number:
UNSPSC Code:
12162002
PubChem Substance ID:
NACRES:
NA.23

vapor pressure

<1 mmHg ( 20 °C)

assay

98%

form

liquid

contains

MEHQ + HQ as stabilizer

refractive index

n20/D 1.419 (lit.)

bp

112-115 °C/0.2 mmHg (lit.)

density

0.918 g/mL at 25 °C (lit.)

SMILES string

CC(=C)C(=O)OCCC[Si](O[Si](C)(C)C)(O[Si](C)(C)C)O[Si](C)(C)C

InChI

1S/C16H38O5Si4/c1-15(2)16(17)18-13-12-14-25(19-22(3,4)5,20-23(6,7)8)21-24(9,10)11/h1,12-14H2,2-11H3

InChI key

BESKSSIEODQWBP-UHFFFAOYSA-N

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

pictograms

Exclamation mark

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Respiratory system

Storage Class

10 - Combustible liquids

wgk_germany

WGK 3

flash_point_f

393.8 °F - closed cup

flash_point_c

201 °C - closed cup

ppe

Eyeshields, Gloves, type ABEK (EN14387) respirator filter


Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Furqan A Maulvi et al.
Acta biomaterialia, 86, 350-362 (2019-01-10)
Contact lenses are ideally suited for extended drug delivery to the ocular tissues, but incorporation of any particulate system affects the critical properties of the contact lens. Timolol loading by the conventional soaking method does not significantly alter the critical
Furqan A Maulvi et al.
International journal of pharmaceutics, 566, 513-519 (2019-06-09)
The optical and swelling properties of gatifloxacin-loaded contact lens decrease owing to the precipitation of gatifloxacin (on hydration) in the matrix structure of the contact lens. This paper focuses on the use of Pluronic F68 both inside and outside (in
Hsiu-Wen Chien et al.
Journal of biomaterials science. Polymer edition, 30(12), 1050-1067 (2019-05-21)
The present work proposes to investigate two series of silicone hydrogel materials for their characterization, water content, surface wettability, transmittance, mechanical property, oxygen permeability (Dk), and bacterial attachment as potential contact lens materials and discuss the relationships between water affinity
Ankita R Desai et al.
Materials science & engineering. C, Materials for biological applications, 112, 110885-110885 (2020-05-16)
A fixed combination of bimatoprost/timolol eye drop solution is used to manage the elevated intra-ocular pressure in glaucoma patients, including individuals whose condition is poorly controlled by monotherapy. Eye drop solutions are generally given in high dose, due to poor
Nguyen-Phuong-Dung Tran et al.
Polymers, 11(6) (2019-06-05)
In this study, silicone-based hydrogel contact lenses were prepared by the polymerization of 3-(methacryloyloxy)propyltris(trimethylsiloxy)silane (TRIS), N,N-dimethylacrylamide (DMA), 1-vinyl-2-pyrrolidinone (NVP), and 2-hydroxyethylmethacrylate (HEMA). The properties of silicone hydrogel lenses were analyzed based on the methods such as equilibrium water content, oxygen

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.