Přejít k obsahu
Merck
Všechny fotografie(3)

Key Documents

379506

Sigma-Aldrich

Tris(2,3-epoxypropyl) isocyanurate

Synonyma:

1,3,5-Tris(oxiran-2-ylmethyl)-1,3,5-triazinane-2,4,6-trione, TGIC, Triglycidyl isocyanurate

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Empirický vzorec (Hillův zápis):
C12H15N3O6
Číslo CAS:
Molekulová hmotnost:
297.26
EC Number:
MDL number:
UNSPSC Code:
12162002
PubChem Substance ID:
NACRES:
NA.23

form

powder

SMILES string

O=C1N(CC2CO2)C(=O)N(CC3CO3)C(=O)N1CC4CO4

InChI

1S/C12H15N3O6/c16-10-13(1-7-4-19-7)11(17)15(3-9-6-21-9)12(18)14(10)2-8-5-20-8/h7-9H,1-6H2

InChI key

OUPZKGBUJRBPGC-UHFFFAOYSA-N

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

signalword

Danger

Hazard Classifications

Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Aquatic Chronic 3 - Eye Dam. 1 - Muta. 1B - Skin Sens. 1 - STOT RE 2

Storage Class

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Airborne contact dermatitis due to triglycidylisocyanurate.
A Dooms-Goossens et al.
Contact dermatitis, 21(3), 202-203 (1989-09-01)
U Erikstam et al.
Contact dermatitis, 44(1), 13-17 (2001-01-13)
Triglycidyl isocyanurate (TGIC) is mainly used in polyester-based powder paints, but also in laminates, insulating varnishes, coatings and adhesives. Several cases of contact allergy to TGIC have been reported during the last 10 years. Contact allergy to TGIC has developed
Occupational contact allergy to triglycidyl isocyanurate (TGIC, Tepic).
K Nishioka et al.
Contact dermatitis, 19(5), 379-380 (1988-11-01)
Martin Roff et al.
The Annals of occupational hygiene, 48(3), 257-265 (2004-04-03)
This paper describes workplace dermal exposure measurements that were carried out by the Health and Safety Laboratory as part of the EU RISKOFDERM project to measure dust contamination. Exposure to dry powder spray paints was measured at five sites on
J Rubin et al.
Cancer treatment reports, 71(5), 489-492 (1987-05-01)
Two schedules of teroxirone, a triazine triepoxide, were evaluated in a phase I study. Twenty-six patients were treated on 1 day every 5 weeks at doses of 36-2250 mg/m2. At doses greater than or equal to 1500 mg/m2, severe thrombophlebitis

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.