Saltar al contenido
Merck
  • Fabrication and application of zinc-zinc oxide nanosheets coating on an etched stainless steel wire as a selective solid-phase microextraction fiber.

Fabrication and application of zinc-zinc oxide nanosheets coating on an etched stainless steel wire as a selective solid-phase microextraction fiber.

Journal of chromatography. A (2015-02-11)
Wenlan Song, Mei Guo, Yida Zhang, Min Zhang, Xuemei Wang, Xinzhen Du
RESUMEN

A novel zinc-zinc oxide (Zn-ZnO) nanosheets coating was directly fabricated on an etched stainless steel wire substrate as solid-phase microextraction (SPME) fiber via previous electrodeposition of robust Zn coating. The scanning electron micrograph of the Zn-ZnO nanosheets coated fiber exhibits a flower-like nanostructure with high surface area. The SPME performance of as-fabricated fiber was investigated for the concentration and determination of polycyclic aromatic hydrocarbons, phthalates and ultraviolet (UV) filters coupled to high performance liquid chromatography with UV detection (HPLC-UV). It was found that the Zn-ZnO nanosheets coating exhibited high extraction capability, good selectivity and rapid mass transfer for some UV filters. The main parameters affecting extraction performance were investigated and optimized. Under the optimized conditions, the calibration graphs were linear over the range of 0.1-200μgL(-1). The limits of detection of the proposed method were 0.052-0.084μgL(-1) (S/N=3). The single fiber repeatability varied from 5.18% to 7.56% and the fiber-to-fiber reproducibility ranged from 6.74% to 8.83% for the extraction of spiked water with 50μgL(-1) UV filters (n=5). The established SPME-HPLC-UV method was successfully applied to the selective concentration and sensitive determination of target UV filters from real environmental water samples with recoveries from 85.8% to 105% at the spiking level of 10μgL(-1) and 30μgL(-1). The relative standard deviations were below 9.7%.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Dietilpirocarbonato, 96% (NT)
Sigma-Aldrich
Dibutyl phthalate, 99%
Sigma-Aldrich
Fosfato de sodio dibasic dodecahydrate, meets analytical specification of Ph. Eur., BP, E339, 98.5-102.5% (T)
Sigma-Aldrich
Dioctyl phthalate, ≥99.5%
Sigma-Aldrich
Dess-Martin periodinane, 97%
Sigma-Aldrich
Naphthalene, 99%
Sigma-Aldrich
Diethyl phthalate, 99.5%
Sigma-Aldrich
Fosfato de sodio dibasic dodecahydrate, BioXtra, ≥99.0% (T)
Sigma-Aldrich
Fosfato de sodio dibasic dodecahydrate, puriss. p.a., crystallized, ≥99.0% (T)
Sigma-Aldrich
Phenanthrene, 98%
Supelco
Filtro SPME Polidimetilsiloxano (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
Filtro SPME Polidimetilsiloxano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Sigma-Aldrich
Anthracene, ReagentPlus®, 99%
Sigma-Aldrich
Dietilpirocarbonato, 96% (NT)
Sigma-Aldrich
Dimethyl phthalate, ≥99%
Sigma-Aldrich
Dietilpirocarbonato, 96% (NT)
Supelco
Filtro SPME Polidimetilsiloxano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Sigma-Aldrich
2-Hydroxy-4-methoxybenzophenone, 98%
Sigma-Aldrich
Poly(dimethylsiloxane), viscosity 1.0 cSt (25 °C)
Sigma-Aldrich
Anthracene, reagent grade, 97%
Sigma-Aldrich
2-Ethylhexyl 4-methoxycinnamate, 98%
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Sigma-Aldrich
2-Ethylhexyl salicylate, 99%
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Sigma-Aldrich
Naphthalene, suitable for scintillation, ≥99%
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Sigma-Aldrich
Diethyl phthalate, ≥99%
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Sigma-Aldrich
Fluoranthene, 98%
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga