Passa al contenuto
Merck
  • Quantitative analysis of unconjugated and total bisphenol A in human urine using solid-phase extraction and UPLC-MS/MS: method implementation, method qualification and troubleshooting.

Quantitative analysis of unconjugated and total bisphenol A in human urine using solid-phase extraction and UPLC-MS/MS: method implementation, method qualification and troubleshooting.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-10-16)
Brigitte Buscher, Dick van de Lagemaat, Wolfgang Gries, Dieter Beyer, Dan A Markham, Robert A Budinsky, Stephen S Dimond, Rajesh V Nath, Stephanie A Snyder, Steven G Hentges
ABSTRACT

The aim of the presented investigation was to document challenges encountered during implementation and qualification of a method for bisphenol A (BPA) analysis and to develop and discuss precautions taken to avoid and to monitor contamination with BPA during sample handling and analysis. Previously developed and published HPLC-MS/MS methods for the determination of unconjugated BPA (Markham et al. Journal of Analytical Toxicology, 34 (2010) 293-303) [17] and total BPA (Markham et al. Journal of Analytical Toxicology, 38 (2014) 194-203) [20] in human urine were combined and transferred into another laboratory. The initial method for unconjugated BPA was developed and evaluated in two independent laboratories simultaneously. The second method for total BPA was developed and evaluated in one of these laboratories to conserve resources. Accurate analysis of BPA at sub-ppb levels is a challenging task as BPA is a widely used material and is ubiquitous in the environment at trace concentrations. Propensity for contamination of biological samples with BPA is reported in the literature during sample collection, storage, and/or analysis. Contamination by trace levels of BPA is so pervasive that even with extraordinary care, it is difficult to completely exclude the introduction of BPA into biological samples and, consequently, contamination might have an impact on BPA biomonitoring data. The applied UPLC-MS/MS method was calibrated from 0.05 to 25ng/ml. The limit of quantification was 0.1ng/ml for unconjugated BPA and 0.2ng/ml for total BPA, respectively, in human urine. Finally, the method was applied to urine samples derived from 20 volunteers. Overall, BPA can be analyzed in human urine with acceptable recovery and repeatability if sufficient measures are taken to avoid contamination throughout the procedure from sample collection until UPLC-MS/MS analysis.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Idrossido di ammonio, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Sodio idrossido, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
Sodio idrossido, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
Idrossido di sodio, 50% in H2O
Sigma-Aldrich
Idrossido di ammonio, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
ter-butil metil etere, ACS reagent, ≥99.0%
Sigma-Aldrich
Ammoniaca, 7 N in methanol
Sigma-Aldrich
Idrossido di sodio, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
β-Glucuronidasi, Type HP-2, aqueous solution, ≥100,000 units/mL
Sigma-Aldrich
Sodio idrossido, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
Idrossido di sodio, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Sodio idrossido, puriss. p.a., ACS reagent, reag. Ph. Eur., K ≤0.02%, ≥98%, pellets
Sigma-Aldrich
Metanolo, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Acido citrico, meets analytical specification of Ph. Eur., BP, USP, E330, anhydrous, 99.5-100.5% (based on anhydrous substance)
Sigma-Aldrich
Sodio idrossido, puriss., meets analytical specification of Ph. Eur., BP, NF, E524, 98-100.5%, pellets
Sigma-Aldrich
Sodio idrossido, reagent grade, 97%, powder
Sigma-Aldrich
Metanolo, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Idrossido di ammonio, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
Sodio idrossido, pellets, semiconductor grade, 99.99% trace metals basis
Sigma-Aldrich
ter-butil metil etere, reagent grade, ≥98%
Sigma-Aldrich
Metanolo, BioReagent, ≥99.93%
Sigma-Aldrich
Metanolo, Absolute - Acetone free
Sigma-Aldrich
Metanolo, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Idrossido di ammonio, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis
Sigma-Aldrich
Idrossido di sodio, 5.0 M
Sigma-Aldrich
Ammoniaca, 0.4 M in dioxane
Sigma-Aldrich
Metanolo, anhydrous, 99.8%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Ammoniaca, 2.0 M in ethanol