KHVEG05TB1
Millipore Express® SHRP, Opticap® XL Capsule
Opticap® XL 5, cartridge nominal length 5 in. (12.5 cm), filter diam. 14.5 cm (5.7 in.)
About This Item
Prodotti consigliati
Materiali
polyester support
polypropylene device (gamma stable)
polypropylene housing
polypropylene vent cap (gamma stable)
polysulfone device
silicone seal
Livello qualitativo
Conformità normativa
meets FDA 21 CFR 177-182 (all component materials)
Sterilità
non-sterile
Compatibilità con la sterilizzazione
gamma compatible
Nome Commerciale
Opticap® XL 5
Caratteristiche
hydrophilic
Produttore/marchio commerciale
Millipore Express®
Parametri
≤13.6 mL/min air diffusion at 3.45 bar (50 psig) (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
tecniche
sterile filtration: suitable
Larghezza
4.2 in.
Lunghezza nominale della cartuccia
5 in. (12.5 cm)
device L
21.6 cm (8.5 in.)
device size
5 in.
Diam. filtro
14.5 cm (5.7 in.)
filter filtration area
0.24 m2
Impurezze
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)
Matrice
Millipore Express® SHR (w/Prefilter)
pore size
0.5/0.1 μm pore size
Punto di bolla
≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water
Raccordi
(38 mm (1 ½ in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)
Cerchi prodotti simili? Visita Guida al confronto tra prodotti
Categorie correlate
Descrizione generale
Confezionamento
Nota sulla preparazione
Gamma Compatible to 45 kGy. May be autoclaved for 3 cycles of 60 min at 123 °C; not in-line steam sterilizable
Risultati analitici
Altre note
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Note legali
Not finding the right product?
Try our Motore di ricerca dei prodotti.
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.