Direkt zum Inhalt
Merck
  • Conventional and novel peripheral blood iron markers compared against bone marrow in Malawian children.

Conventional and novel peripheral blood iron markers compared against bone marrow in Malawian children.

Journal of clinical pathology (2014-06-12)
Femkje A M Jonker, Michael Boele van Hensbroek, Tjalling Leenstra, Raymond J W M Vet, Bernard J Brabin, Nelson Maseko, Montfort B Gushu, Mercy Emana, Rob Kraaijenhagen, Harold Tjalsma, Dorine W Swinkels, Job C J Calis
ZUSAMMENFASSUNG

Iron deficiency is an important child health problem. Its diagnosis in areas of high infection exposure remains complicated as inflammation may interfere with the accuracy of peripheral iron markers. With this study, we aimed to validate the conventional iron markers and two novel iron markers, hepcidin and Red blood cell Size Factor (RSf), against the reference standard of iron status, bone marrow iron, in children living in an infectious setting. We compared ferritin, soluble transferrin receptor, Soluble Transferrin Log-Ferritin Index (sTfR-F), mean cellular volume, mean cellular haemoglobin concentration, hepcidin and RSf, against bone marrow iron in 87 healthy Malawian children (6-66 months) scheduled for elective surgery. Of all children, 44.8% had depleted bone marrow iron stores. Using optimised cut-offs, ferritin (<18 µg/L) and sTfR-F (>1.85) best predicted depleted iron stores with a sensitivity/specificity of 73.7%/77.1% and 72.5%/75.0%, respectively. Hepcidin (<1.4 nmol/L) was a moderate sensitive marker (73.0%) although specificity was 54.2%; RSf poorly predicted depleted iron stores. We provide the first bone marrow-validated data on peripheral iron markers in African children, and showed ferritin and sTfR-F best predicted iron status. Using appropriately defined cut-offs, these indicators can be applied in surveillance and research. As their accuracy is limited for clinical purposes, more reliable iron biomarkers are still required in African children.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Eisen, ≥99%, reduced, powder (fine)
Sigma-Aldrich
Ferritin aus Pferdemilz, Type I, saline solution
Sigma-Aldrich
Carbonyleisen, ≥97% Fe basis
Sigma-Aldrich
Eisen, puriss. p.a., carbonyl-Iron powder, low in magnesium and manganese compounds, ≥99.5% (RT)
Sigma-Aldrich
Eisen, powder, −325 mesh, 97%
Sigma-Aldrich
Eisen, granular, 10-40 mesh, >99.99% trace metals basis
Sigma-Aldrich
Eisen, foil, thickness 0.1 mm, ≥99.9% trace metals basis
Sigma-Aldrich
Eisen, chips, 99.98% trace metals basis
Sigma-Aldrich
Eisen, wire, diam. 1.0 mm, ≥99.9% trace metals basis
Sigma-Aldrich
Ferritin from human liver, Type IV, 10 μg/mL
Eisen, foil, 100x100mm, thickness 0.25mm, hard, 99.5%
Sigma-Aldrich
Eisen, foil, thickness 0.25 mm, ≥99.99% trace metals basis
Sigma-Aldrich
Ferritin from human spleen, Type V, 10 μg/mL in 0.15 M NaCl, 10 mM Tris, pH 8.0, containing 0.1% sodium azide
Eisen, foil, 300x300mm, thickness 0.1mm, hard, 99.5%
Eisen, foil, 100x100mm, thickness 0.125mm, as rolled, 99.99+%
Eisen, rod, 200mm, diameter 25mm, as drawn, 98+%
Eisen, tube, 200mm, outside diameter 8.0mm, inside diameter 5mm, wall thickness 1.5mm, annealed, 99.5%
Eisen, rod, 100mm, diameter 100mm, as drawn, armcO« soft ingot 99.8%
Eisen, foil, 100x100mm, thickness 1.0mm, as rolled, 99.5%
Eisen, rod, 50mm, diameter 5.0mm, as drawn, 99.99+%
Eisen, foil, 100x100mm, thickness 0.5mm, hard, 99.5%
Eisen, foil, 150x150mm, thickness 1.5mm, as rolled, 99.5%
Eisen, rod, 150mm, diameter 6.0mm, as drawn, 99.99+%
Eisen, rod, 100mm, diameter 2.0mm, as drawn, 99.95%
Eisen, foil, 25x25mm, thickness 0.9mm, as rolled, 99.5%
Eisen, tube, 200mm, outside diameter 5.0mm, inside diameter 4.5mm, wall thickness 0.25mm, as drawn, 99.5%
Eisen, foil, 25x25mm, thickness 1.0mm, as rolled, 99.5%
Eisen, foil, 50x50mm, thickness 0.1mm, hard, 99.5%
Eisen, rod, 200mm, diameter 9.5mm, as drawn, soft ingot 99.8+%
Eisen, rod, 500mm, diameter 4.8mm, as drawn, 98+%