Direkt zum Inhalt
Merck

59352-U

Supelco

Discovery® C8 (5 µm) HPLC Columns

L × I.D. 5 cm × 4.6 mm, HPLC Column

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
41115700
eCl@ss:
32110501
NACRES:
SB.52

product name

HPLC-Säule Discovery® C8, 5 μm particle size, L × I.D. 5 cm × 4.6 mm

Materialien

stainless steel column

Agentur

suitable for USP L7

Produktlinie

Discovery®

Leistungsmerkmale

endcapped

Hersteller/Markenname

Discovery®

Verpackung

1 ea of

Kennzeichnungsgrad

7.5% Carbon loading

Parameter

≤70 °C temp. range
400 bar pressure (5801 psi)

Methode(n)

HPLC: suitable
LC/MS: suitable

L × ID

5 cm × 4.6 mm

Oberflächenbereich

200 m2/g

Oberflächendeckung

3.4 μmol/m2

Verunreinigungen

<10 ppm metals

Matrix

silica gel, high purity, spherical base material
fully porous particle

Aktive Matrixgruppe

C8 (octyl) phase

Partikelgröße

5 μm

Porengröße

180 Å

operating pH range

2-8

Anwendung(en)

food and beverages

Trenntechnik

reversed phase

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Leistungsmerkmale und Vorteile

  • Ausgezeichnete Reproduzierbarkeit
  • Schnellere Trennung von stark hydrophoben Analyten als bei C18-Säulen
  • Stabile, gering blutende LC-MS-Trennungen
  • Hervorragende Peakformen bei basischen und sauren Analyten
  • Kompatibel mit schwach organischen/hochwässrigen mobilen Phasen

Rechtliche Hinweise

Discovery is a registered trademark of Merck KGaA, Darmstadt, Germany

Vorsäulenkartusche

Produkt-Nr.
Beschreibung
Preisangaben

Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

G L Bundy et al.
The Journal of biological chemistry, 261(2), 747-751 (1986-01-15)
The gorgonian coral Pseudoplexaura porosa contains a lipoxygenase capable of converting exogenous arachidonic acid into (8R)-8-hydroperoxy-5,9,11,14-eicosatetraenoic acid. The (8R)- (or 8-L-) configuration in this product, opposite to that observed in previously reported 8-lipoxygenase products, was determined unambiguously by comparison of
M Q Zhang et al.
Die Pharmazie, 46(10), 687-700 (1991-10-01)
The rapid growth in the quinolone research changed the whole face of the previous SAR concepts. So far structural modifications at all positions of the quinolone nucleus except the 4-oxo group have successfully lead to the discovery of potent antimicrobial
Hugo M Botelho et al.
Scientific reports, 5, 9038-9038 (2015-03-13)
Plasma membrane proteins are essential molecules in the cell which mediate interactions with the exterior milieu, thus representing key drug targets for present pharma. Not surprisingly, protein traffic disorders include a large range of diseases sharing the common mechanism of
Simeon Grazio et al.
Clinical and experimental rheumatology, 31(5), 665-671 (2013-06-07)
Using proteomic approach in this study, we sought to identify proteins with heparin affinity associated with rheumatoid arthritis (RA), psoriatic arthritis (PsA) and non-inflammatory arthritis (NIA). Plasma samples from adult RA, PsA and NIA patients, 20 of each, were collected.
Wai Shun Mak et al.
Nature communications, 6, 10005-10005 (2015-11-26)
The ability to biosynthetically produce chemicals beyond what is commonly found in Nature requires the discovery of novel enzyme function. Here we utilize two approaches to discover enzymes that enable specific production of longer-chain (C5-C8) alcohols from sugar. The first

Verwandter Inhalt

Discovery C18 and C8 HPLC Columns products offered

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.