Direkt zum Inhalt
Merck

S2GPT10RE

Millipore

Millipore® Steritop® Vakuumflaschenaufsatzfilter

Millipore® Steritop® Vacuum Bottle Top Filter

pore size 0.22 μm, polyethersulfone membrane, funnel capacity 1000 mL, pack of 12 ea

Synonym(e):

SCGPT10RE, Steritop Flaschenaufsatzfilter mit Gewinde

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

12 FILTERS
CHF 381.00

CHF 381.00


Voraussichtliches Versanddatum09. April 2025


Weitere Informationen anfragen

Größe auswählen

Ansicht ändern
12 FILTERS
CHF 381.00

About This Item

UNSPSC-Code:
41104914
eCl@ss:
32031623
NACRES:
NB.24

CHF 381.00


Voraussichtliches Versanddatum09. April 2025


Weitere Informationen anfragen

Materialien

polyethersulfone membrane
polystyrene funnel(s)
polystyrene housing

Qualitätsniveau

Sterilität

sterile; irradiated

Produktlinie

Steritop®

Leistungsmerkmale

hydrophilic

Verpackung

pack of 12 ea

Parameter

45 °C max. temp.

Beschreibung

2.4 mL (hold-up volume)

Methode(n)

sterile filtration: suitable

Höhe

169 mm

Kapazität

1000 mL

Durchmesser

13.5 cm

Filterdurchm.

73 mm

Filtrationsfläche

40 cm2

Trichterkapazität

1000 mL

Matrix

Express PLUS

Porengröße

0.22 μm pore size

Fitting

inlet funnel
45 mm outlet thread(s)

Versandbedingung

ambient

Allgemeine Beschreibung

Die Stericup® und Steritop® Filtersysteme bieten mühelose Handhabung und zuverlässige Filtrierung.

Die Stericup® und Steritop® Systeme für die Sterilfiltration verwenden zuverlässige Hochleistungsmembranen für eine optimale Sterilfiltration von Laborreagenzien, Puffern und Medien. Diese Einheiten bieten hervorragende Durchfluss- und Durchsatzraten mit geringer unspezifischer Bindung und ein stabiles Design mit Kippschutz.

Dieser Steritop® 1000-ml-Flaschenaufsatz mit einer Membranfiltereinheit aus Polyethersulfon (PES) mit einer Porengröße von 0,22 μm kann auf Flaschen mit 45-mm-Öffnung aufgesetzt werden und ist für Vakuumanwendungen bestimmt.
Dieses Produkt ist ein direkter Ersatz für SCGPT10RE

Anwendung

Die Stericup® und Steritop® Systeme sind dazu ausgelegt, Schaumbildung und Proteindenaturierung zu reduzieren und gleichzeitig den Durchfluss zu maximieren. Sie eignen sich für die sterile Vakuumfiltration von wässrigen Lösungen wie Gewebekulturmedien und biologischen Flüssigkeiten.

  • Gewebekulturmedien +/- Additive
  • Puffer
  • Biologische Lösungen
Nur für Forschungszwecke

Leistungsmerkmale und Vorteile

Die fettgedruckte Produktkennzeichnung auf dem Steritop® Filtertrichter zeigt deutlich die Membraneigenschaften einschließlich Zusammensetzung und Porengröße an und ermöglicht so eine unmittelbare, anwendungsgerechte Produktauswahl.

Rechtliche Hinweise

EXPRESS PLUS is a trademark of Merck KGaA, Darmstadt, Germany
Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
STERITOP is a registered trademark of Merck KGaA, Darmstadt, Germany

Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Artikel

Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.

Verwandter Inhalt

This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.

Questions

1–10 of 15 Questions  
  1. What tubing can be used with Stericup® and Steritop® vacuum filters?

    What tubing can be used with Stericup® and Steritop® vacuum filters?

    1 answer
    1. Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004

      Helpful?

  2. What leachables are detected during filtration processes using Stericup® filters?

    1 answer
    1. We have not performed extractables/leachables studies for our Stericup® filters.

      Helpful?

  3. What is the maximum vacuum pressure for filtration?

    1 answer
    1. 700 mm Hg (27.5” Hg, 0.9 bar) differential vacuum at 25 °C (77 °F)

      Helpful?

  4. Can Stericup® and Steritop® filters be reused?

    1 answer
    1. All Stericup® and Steritop® filters were developed for single use, disposable processing.

      Helpful?

  5. The User Guide says “Use only glass or plastic bottles designed for vacuum applications”. Can you specify which bottles are compatible?

    1 answer
    1. Steritop® Quick Release bottle top units require a vacuum-rated receiver bottle with either a GL33 or GL45 mm closure thread as specified. Steritop® E bottle top units require a vacuum-rated receiver bottle with a GL45 mm closure thread. Bottles no larger than 2 L should be used.
      Glass bottles, GL33:
      • Wheaton media bottles (glass), 500 mL (Product Z364886)
      • Wheaton media bottles (glass), 1 L (Product Z364894)
      Glass bottles, GL45
      • Corning® glass media storage bottle, 125 mL (Product CLS1399125)
      • Corning® glass media storage bottle, 250 mL (Product CLS1399250)
      • Corning® glass media storage bottle, 500 mL (Product CLS1399500)
      • Corning® glass media storage bottle, 1 L (Product CLS13991L)
      • Pyrex® round media storage bottle, 500 mL (Product CLS1395500)
      • Pyrex® round media storage bottle, 1 L (Product CLS13951L)
      • KIMBLE® KIMAX® Media bottle, 250 mL (Product DWK14395250)
      • KIMBLE® KIMAX® Media bottle, 500 mL (Product DWK14395500)
      • KIMBLE® KIMAX® Media bottle, 1 L (Product DWK143951000)
      Plastic (pre-sterile) bottles, GL45:
      • Stericup® Quick Release Receiver flask, 250 mL (Product S200B02RE)
      • Stericup® Quick Release Receiver flask, 500 mL (Product S200B05RE)
      • Stericup® Quick Release Receiver flask, 1000 mL (Product S200B10RE)

      Helpful?

  6. What is the difference between classic Stericup® filters and Stericup® “Quick Release” filters?

    1 answer
    1. Stericup® Quick Release, or “QR”, filters feature a connection between funnel filter and receiver bottle that requires only a quarter-turn release to facilitate funnel removal. These filters come fully engaged – there is no need to tighten before use. The receiver bottle cap has flanges on the top surface to improve grip, as well as a positive lock stop to ensure a leak-proof seal with the receiver bottle. Other improvements include a large, frosted writing surface on the receiver bottle and a lighter cap color to facilitate labelling, more prominent volume markings on the filtration funnel and receiver bottle, and a product label with a peel-off lot record strip on the bag for easy viewing in storage.

      Helpful?

  7. What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?

    1 answer
    1. All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
      *Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.

      Helpful?

  8. What Bacterial Endotoxins Test is used?

    1 answer
    1. The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.

      Helpful?

  9. Are Stericup® and Steritop® filters GMP-certified?

    1 answer
    1. No, Stericup® and Steritop® devices are not GMP-approved.

      Helpful?

  10. What is the chemical compatibility of the various Stericup® and Steritop® filters?

    What is the chemical compatibility of the various Stericup® and Steritop® filters?

    1 answer
    1. Helpful?

1–10 of 15 Questions  

Reviews

Active Filters

  1. 1 Ratings-Only Review

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.