KPHLS10HH1
Durapore® 0,45 µm, Opticap®-XL-Kapsel
Opticap® XL 10, cartridge nominal length 13.2 in. (33.5 cm), filter diam. 4.2 in. (10.7 cm)
About This Item
Empfohlene Produkte
Materialien
polyester support
polyethylene support
polypropylene filter
polypropylene housing
silicone outer O-ring
silicone-coated EPDM rubber lead O-ring
Qualitätsniveau
Einhaltung gesetzlicher Vorschriften
FDA 21CFR177-182 (all component materials)
Sterilität
sterile; irradiated
Produktlinie
Opticap® XL 10
Leistungsmerkmale
hydrophilic
Hersteller/Markenname
Opticap®
Parameter
≤15.0 mL/min air diffusion at 3.9 bar (56 psig) and 23 °C (in water)
1 bar max. inlet pressure (15 psi) at 80 °C
2.1 bar max. differential pressure (30 psid) at 4-40 °C (Reverse:)
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
4.1 bar max. differential pressure (60 psid) at 25 °C (Forward:)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
Methode(n)
bioburden reduction: suitable
Nennlänge Kartusche
13.2 in. (33.5 cm)
device L
33.5 cm (13.2 in.)
device size
10 in.
Filterdurchm.
4.2 in. (10.7 cm)
filter filtration area
0.62 m2
Durchm. Einlassanschluss
9/16 in.
inlet to outlet width
33.5 cm (13.2 in.)
Durchm. Auslassanschluss
9/16 in.
Verunreinigungen
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL bacterial endotoxins (LAL test, sample aqueous extraction)
Matrix
Durapore®
Porengröße
0.45 μm pore size
Blasenpunkt
≥1930 mbar (28 psig), air with water at 23 °C
Fitting
1/4 in. fitting (vent/drain hose barb with double O-ring seal)
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)
Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich
Allgemeine Beschreibung
Angaben zur Herstellung
Gamma compatible to 40 kGy. 3 autoclave cycles of 60min at 126°C; not in-line steam sterilizable
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21CFR210.3(b)(6).
Hinweis zur Analyse
Sonstige Hinweise
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of Opticap® XL Capsules and Opticap® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Rechtliche Hinweise
Not finding the right product?
Try our Produkt-Auswahlhilfe.
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.