Direkt zum Inhalt
Merck

CWSC03S03

Millipore

Milligard® 1.2/0.5 µm nominal, Cartridge

cartridge nominal length 30 in. (75 cm), Code 0 (2-222; O-rings), pore size 1.2/0.5 μm

Synonym(e):

Milligard Cartridge Filter 30 in. Code 0 0.5 μm

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
23151806
eCl@ss:
32031610

Materialien

mixed cellulose esters (MCE) membrane
polyester support
polypropylene
silicone seal

Qualitätsniveau

Einhaltung gesetzlicher Vorschriften

meets EU framework regulation [1935/2004/EC] (all component materials; regarding materials and articles intended to contact food)
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Sterilität

non-sterile

Kompatibilität mit Sterilisationsverfahren

autoclavable compatible
steam-in-place compatible

Produktlinie

Milligard®

Leistungsmerkmale

hydrophilic

Hersteller/Markenname

Milligard®

Parameter

3.5 bar max. differential pressure (50 psid) at 25 °C
3.5 bar max. inlet pressure (50 psi) at 25 °C

Methode(n)

prefiltration: suitable

Länge

30 in.

Breite

2.9 in.

Nennlänge Kartusche

30 in. (75 cm)

Durchmesser

7.1 cm (2.8 in.)

Filtrationsfläche

2.1 m2

Verunreinigungen

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

Gravimetrisch bestimmte extrahierbare Substanzen

≤150 mg/cartridge

Matrix

Milligard®

pore size

1.2/0.5 μm nominal pore size
1.2/0.5 μm pore size

Aufnahme

sample type liquid

Kartuschencode

Code 0 (2-222; O-rings)

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Device Configuration: Filterelement

Leistungsmerkmale und Vorteile

Format: Double Layer

Verpackung

Leicht zu öffnender Doppelbeutel

Sonstige Hinweise

Diese Produkte werden in einem Werk hergestellt, das den GMP-Richtlinien der FDA entspricht.
Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer to the installation and wetting sections of OptiScale®-25 user guide and introduction section of the Mixed cellulose esters Tech Brief
  • Storage Statement: Please refer to the Mixed cellulose esters Tech Brief
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Spezifikationen

Filter Grade: Standard Milligard® Media

Angaben zur Herstellung

Sterilization Method
10 Autoklaven- oder In-situ-Dampfsterilisationszyklen von 30 min bei 121 °C
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Hinweis zur Analyse

Erfüllt die Anforderungen des USP-Tests auf oxidierbare Substanzen nach Durchspülen mit ≥6 l Wasser
Gravimetric Extractables: after 24 hours in water at controlled room temperature

Rechtliche Hinweise

MILLIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
OptiScale is a registered trademark of Merck KGaA, Darmstadt, Germany

Not finding the right product?  

Try our Produkt-Auswahlhilfe.

Piktogramme

Flame

Signalwort

Danger

H-Sätze

Gefahreneinstufungen

Flam. Sol. 1

Lagerklassenschlüssel

4.1B - Flammable solid hazardous materials

WGK

WGK 2


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.