If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
Wichtige Dokumente
306312
Inhibitorentferner
Prepacked column for removing hydroquinone and monomethyl ether hydroquinone
Synonym(e):
Inhibition Removal Agents
Größe auswählen
Größe auswählen
About This Item
Empfohlene Produkte
Dampfdruck
17 mmHg ( 20 °C)
Form
beads
Säulengröße
17 mm × 240 mm
SMILES String
[Al]21O[Al](O2)O1
InChI
1S/2Al.3O
InChIKey
TWNQGVIAIRXVLR-UHFFFAOYSA-N
Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich
Verwandte Kategorien
Allgemeine Beschreibung
• Geeignet für Anwendungen, bei denen der Stabilisator oder Inhibitor (Hydrochinon (HQ), Hydrochinon-Monomethylether (MEHQ, 4-Methoxyphenol) oder 4-tert-Butylcatechol (TBC)) vor der Verwendung entfernt werden muss.
• Verbrauchte Säulen können entsorgt1 oder wiederverwendet werden, indem die Säule zu ca. 3/4 mit neuem Packungsmaterial gefüllt wird. Nachfüllvolumen für HQ/MEHQ-Säulen: ~21 g Nachfüllvolumen für TBC-Säulen:~30 g.
• Säulenkapazität (ca.):
HQ/MEHQ: 3 l bei 100 ppm
TBC: 4 l bei 15 ppm
• Die Verwendung von TBC-Säulen und -Packungen mit polaren Lösungsmitteln, einschließlich Acrylsäure, wird nicht empfohlen. Für derartige Anwendungen sollte die Vakuumdestillation verwendet werden.
Einfache Anwendung:
1. Es wird empfohlen, die vorverpackten Glassäulen mit einer geringen Menge Monomer vorzuwaschen.
2. Geben Sie das Monomer (oder Lösungsmittel) in einen Zugabetrichter, der über der Säule befestigt wird.
3. Geben Sie das Monomer tröpfchenweise in die Säule. Beobachten Sie die zugeführte Menge, um ein Überlaufen der Säule zu vermeiden. Fangen Sie das Monomer in einem geeigneten Behälter auf.
4. Achten Sie darauf, dass die Säulentemperatur bei Feststoff-Monomeren mit niedrigem Schmelzpunkt während der Verwendung über dem Schmelzpunkt liegt.
Achtung: Eine Überhitzung kann zu einer Polymerisierung an der Säule führen. Viskose Monomere oder Monomere mit hohem Schmelzpunkt können vor der Säulenzugabe in einem geeigneten Lösungsmittel verdünnt werden.
1Nicht verbrauchte Säulen können zusammen mit anderen chemischen Feststoffabfällen entsorgt werden. Nach der Verwendung müssen die Toxizität und andere mit dem Monomer, von dem der Inhibitor entfernt wurde, verbundenen Gefahren bei Entscheidungen hinsichtlich der Entsorgung des Packungsmaterials und der Säule berücksichtigt werden.
Anwendung
Lagerklassenschlüssel
11 - Combustible Solids
WGK
WGK 3
Flammpunkt (°F)
Not applicable
Flammpunkt (°C)
Not applicable
Persönliche Schutzausrüstung
Eyeshields, Gloves, type N95 (US)
Hier finden Sie alle aktuellen Versionen:
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Kunden haben sich ebenfalls angesehen
Artikel
An article regarding common FAQs for initiators and stabilizers.
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
Helpful?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Helpful?
-
-
Would these work for removal of Topanol A, 2,4-Dimethyl-6-tert-butylphenol CAS Number:1879-09-0?
1 answer-
This product is not tested for removal of Topanol A, but is expected to be suitable. The product is used for inhibitor removal for product 276685. Methacrylic anhydride, which contains 2,000 ppm Topanol A as inhibitor.
Helpful?
-
-
Which side of the column is the top versus the bottom?
1 answer-
The label is placed at the top of the column and will include the lot number. The column is provided with a cap on each end; these caps would need to be removed when the column is in use, but replaced between uses.
The glass wool plugs are present to hold the beads inside the column. Initially, a small volume of liquid will wet the glass wool. As more volume is added, the column will become saturated and then eventually pass through and out at the bottom of the column.
Helpful?
-
-
Can Product 306312, Inhibitor removers - Prepacked column for removing hydroquinone and monomethyl ether hydroquinone, be used to remove butylated hydroxytoluene (BHT)?
1 answer-
This inhibitor remover is not intended to remove BHT present in a monomer solution; little, if any, BHT will be removed with this column. Unfortunately, Sigma-Aldrich does not currently offer a inhibitor-remover column that will accomplish this purpose.
Helpful?
-
-
How much can Product 306312, Inhibitor removers - Prepacked column for removing hydroquinone and monomethyl ether hydroquinone, hold at one time?
1 answer-
This product has a bed volume of approximately 30 mL.
Helpful?
-
-
Can Product 306312, Inhibitor removers - Prepacked column for removing hydroquinone and monomethyl ether hydroquinone, be used more than once?
1 answer-
This pre-packed inhibitor remover column is meant for single use but can be rinsed and reused. If time will pass between uses, this column can be rinsed with methanol, dried, capped on both ends, and stored in a tightly sealed plastic bag in the freezer at -20°C.
Helpful?
-
-
What is the flow rate for Product 306312, Inhibitor removers - Prepacked column for removing hydroquinone and monomethyl ether hydroquinone?
1 answer-
According to the manufacturer of this inhibitor removal column, the maximum recommended flow rate is 4 bed volumes (approximately 120 mL) per hour.
Helpful?
-
-
What is the Department of Transportation shipping information for this product?
1 answer-
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
Helpful?
-
Active Filters
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.