Accéder au contenu
Merck
Toutes les photos(2)

Documents

11578553001

Roche

PCR Core Kit

sufficient for ≤100 reactions, kit of 1 (5 components), suitable for PCR

Synonyme(s) :

PCR

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41106300

Utilisation

sufficient for ≤100 reactions

Niveau de qualité

Conditionnement

kit of 1 (5 components)

Fabricant/nom de marque

Roche

Paramètres

72 °C optimum reaction temp.

Technique(s)

PCR: suitable

pH optimal

~9.0 (20 °C)

Température de stockage

−20°C

Description générale

The PCR Core Kit supplies all reagents (polymerase, buffers, dNTPs, etc.) for optimizing conventional PCRs of a specific template with maximum sensitivity, and specifcity. For convenience, each reagent component in the kit is supplied in a separate vial. This allows the user to easily change the amount of polymerase, dNTPs, and MgCl2 in the reaction mix. Most importantly, the kit allows easy optimization of the Mg2+ concentration, one of the most crucial variables in the PCR.

Application

Principle

PCR is an in vitro method for enzymatically synthesizing defined sequences of DNA. The reaction uses two oligonucleotide primers that hybridize to opposite strands and flank the target DNA sequence to be amplified. A repetitive series of cycles involving template denaturation, primer annealing, and extension of the annealed primers by DNA polymerase results in the accumulation of a specific DNA fragment, the termini of which are defined by the 5′-ends of the primers.

Because the primer extension products synthesized in a given cycle can serve as a template in the next cycle, the number of target DNA copies approximately doubles every cycle; thus, 20 cycles of PCR yield about a million copies (220) of the target DNA. Primer elongation is catalyzed by Taq DNA Polymerase, a heat-stable DNA polymerase isolated from the thermophilic eubacterium Thermus aquaticus BM.
The PCR Core Kit is designed to determine individual PCR conditions for all basic PCR applications relying on Taq DNA Polymerase. Assays which might give better sensitivity and specificity with a non-standard Mg-concentration in the reaction buffer can be optimized using the Mg-free buffer supplied with this kit.

Conditionnement

1 kit containing 5 components.

Qualité

Each lot is PCR tested using λDNA. Each lot is also tested for the absence of exo- and endonucleases, and nicking activities according to the current Quality Control procedures.

Autres remarques

Contents

  • Taq DNA Polymerase, 250 U, 5 U/μl in storage buffer: 20 mM Tris-HCl, 100 mM dithiothreitol, 0.1 mM EDTA, 0.5% Nonidet P40 (v/v), 0.5% Tween 20 (v/v), 50% glycerol (v/v), pH 8.0 (+4°C)
  • dNTP stock solution, 200 μl, containing each 10 mM dATP, dCTP, dGTP, dTTP, in sterile double-distilled water, pH 7.0
  • PCR reaction buffer, 10x concentrated, 2 x 1 ml, 100 mM Tris-HCl, 15 mM MgCl2, 500 mM KCl, pH 8.3 (+20°C)
  • 25 mM MgCl2 stock solution, 1 ml
  • PCR reaction buffer without MgCl2, 10x concentrated, 1 ml, 100 mM Tris-HCl, 500 mM KCl, pH 8.3 (+20°C)
For life science research only. Not for use in diagnostic procedures.

Informations légales

Use of this product is covered by US Patent No. 6,127,155 and corresponding patent claims outside the US.  The purchase of this product includes a limited, non-transferable immunity from suit under the foregoing patent claims for using only this amount of product for the purchaser′s own internal research.  No right under any other patent claim and no right to perform commercial services of any kind, including without limitation reporting the results of purchaser′s activities for a fee or other commercial consideration, is conveyed expressly, by implication, or by estoppel.  This product is for research use only. Human and veterinary diagnostic uses under Roche patent claims require a separate license from Roche.  All uses other than internal research and human and veterinary diagnostic uses under Roche patent claims require a separate license from Thermo Fisher Scientific. Further information on purchasing licenses from Roche may be obtained by contacting the Licensing Department of Roche Molecular Systems, Inc., 4300 Hacienda Drive, Pleasanton, California 94588, USA or Roche Diagnostics GmbH, Sandhofer Strasse 116, 68305 Mannheim, Germany.  Further information on purchasing licenses from Thermo Fisher Scientific may be obtained by contacting the Licensing Department of  Thermo Fisher Scientific, 5791 Van Allen Way, Carlsbad, California 92008, USA.

Composants de kit seuls

Réf. du produit
Description

  • Taq DNA Polymerase, in storage buffer 5 U/μl

  • dNTP Stock Solution

  • PCR Reaction Buffer

  • MgCl2 Stock Solution

  • PCR Reaction Buffer without MgCl2

Mentions de danger

Conseils de prudence

Classification des risques

Aquatic Chronic 3

Code de la classe de stockage

12 - Non Combustible Liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

does not flash

Point d'éclair (°C)

does not flash


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Ivo J H M de Vos et al.
Biology open, 9(12) (2020-11-26)
Frank-Ter Haar syndrome (FTHS, MIM #249420) is a rare skeletal dysplasia within the defective collagen remodelling spectrum (DECORS), which is characterised by craniofacial abnormalities, skeletal malformations and fibrotic soft tissues changes including dermal fibrosis and joint contractures. FTHS is caused

Articles

Learn how water impurities can affect PCR and related methodologies. High purity water purified using ultrafiltration is suitable for PCR and related techniques.

Learn how water impurities can affect PCR and related methodologies. High purity water purified using ultrafiltration is suitable for PCR and related techniques.

Learn how water impurities can affect PCR and related methodologies. High purity water purified using ultrafiltration is suitable for PCR and related techniques.

Learn how water impurities can affect PCR and related methodologies. High purity water purified using ultrafiltration is suitable for PCR and related techniques.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique