KTGRA04HH3
Aervent® 0,2 µm, capsule Opticap® XL
inlet connection diam. 9/16 in., Opticap® XL 4, pore size 0.2 μm, cartridge nominal length 7.6 in. (19.3 cm)
Synonyme(s) :
Opticap Sterilizing Grade XL4 Aervent 0.2 µm 9/16 in. HB/HB
About This Item
Produits recommandés
Matériaux
PTFE
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal
Niveau de qualité
Stérilité
non-sterile
Mode de stérilisation compatible
autoclavable compatible
Gamme de produits
Opticap® XL 4
Caractéristiques
hydrophobic
Fabricant/nom de marque
Opticap®
Paramètres
≤9 mL/min nitrogen diffusion at 965 mbar (14 psig) and 23 °C (in 70/30% IPA/water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
4.1 bar max. differential pressure (60 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
Technique(s)
gas filtration: suitable
Longueur
7.7 in.
Largeur
3.3 in.
Longueur nominale des cartouches
7.6 in. (19.3 cm)
Diamètre
8.4 cm (3.3 in.)
Surface de filtration
0.21 m2
Diam. du raccord d'entrée
9/16 in.
Largeur, de l'entrée à la sortie
19.3 cm (7.6 in.)
Diam. du raccord de sortie
9/16 in.
Impuretés
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Extractibles par gravimétrie
≤15 mg
Matrice
Aervent®
Dimension de pores
0.2 μm pore size
Point de bulle
≥1100 mbar (16 psig), nitrogen with 70/30% IPA/water at 23 °C
Raccords
1/4 in. drain/vent hose barb (with double O-ring Seal)
inlet hose barb
outlet hose barb
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)
Description générale
Conditionnement
Liaison
Notes préparatoires
30 autoclave cycles of 30 min @ 135 °C; not in-line steam sterilizable
Remarque sur l'analyse
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Autres remarques
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Informations légales
Clause de non-responsabilité
Vous ne trouvez pas le bon produit ?
Essayez notre Outil de sélection de produits.
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique