Accéder au contenu
MilliporeSigma
Toutes les photos(1)

Documents

1.50436

Supelco

SeQuant® ZIC®-HILIC 200Å (5 µm) HPLC Columns

L × I.D. 20 mm x 2.1 mm, Guard Kit with holder and Guard Column

Synonyme(s) :

Hydrophilic Interaction Liquid Chromatography Guard Column

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41115709

product name

SeQuant® ZIC-HILIC Guard Kit 20 x 2.1 mm, PEEK-lined stainless steel column, pkg of 3 column

Matériaux

PEEK-lined stainless steel column

Niveau de qualité

Agence

suitable for USP L114

Gamme de produits

SeQuant®

Caractéristiques

endcapped: no

Conditionnement

pkg of 3 column

Paramètres

550 bar pressure
70 °C max. temp.

Technique(s)

LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable (High)

Colonne, L × D.I.

2 cm × 2.1 mm

Matrice

fully porous particle

Groupe de la matrice active

ZIC-HILIC bonding phase

Taille des particules

5 μm

Dimension de pores

200 Å pore size

pH de fonctionnement

2-7.5

Technique de séparation

hydrophilic interaction (HILIC)

Température de stockage

no temp limit

Catégories apparentées

Description générale

The SeQuant® ZIC®-HILIC Guard column protects your analytical column from contamination. The guard column kit contains 3 Guard columns including the coupler.
SeQuant® ZIC®-HILIC Columns are designed to retain and separate all types of polar and hydrophilic compounds and for robust chromatography with high selectivity and reproducibility.
The silica-based ZIC®-HILIC sorbent has a bonded stationary phase consisting of a highly polar, permanent zwitterion. Separation selectivity is favored by the 1:1 zwitterion charge balance, which makes the ZIC®-HILIC Column overall neutral, with weak, but important, ionic interactions. Tuning of the selectivity on the ZIC®-HILIC Column during method development is facilitated by the pH-inpendent permanent zwitterion, ensuring that only the analytes (and not the column) are affected during eluent optimization.
Thanks to their favorable retention and robust performance, SeQuant® HILIC columns have become extremely popular in numerous laboratories around the world. For example, US FDA (United States Food and Drug Administration) has recommended SeQuant® ZIC®-HILIC for analysis of melamine and related substances.
SeQuant® HILIC columns excel in stability and low bleed. These features make them particularly suitable for LC-MS applications where high background can lead to signal suppression and interference with quantitative measurements while also increasing instrument wear. Their high stability makes these high-performance HILIC columns also attractive for traditional HPLC applications.
Learn more about the Supelco HPLC Column portfolio and Method development:
Brochure: HPLC and UHPLC Column Selection Guide
Brochure: A Practical Guide to HPLC - Method Development Guide

Informations légales

SeQuant is a registered trademark of Merck KGaA, Darmstadt, Germany
ZIC is a registered trademark of Merck KGaA, Darmstadt, Germany
ZIC-HILIC is a trademark of Merck KGaA, Darmstadt, Germany

Produit(s) apparenté(s)

Réf. du produit
Description
Tarif

Code de la classe de stockage

11 - Combustible Solids


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique