50297-U
Ascentis® Express 90 Å HILIC (5 μm) HPLC Columns
L × I.D. 5 mm × 3 mm, HPLC Guard Cartridge, pkg of 3 ea
About This Item
Nome do produto
Ascentis® Express HILIC, 5 μm Guard Cartridge, 5 μm particle size, L × I.D. 5 mm × 3 mm, pkg of 3 ea
Materiais
stainless steel column
Nível de qualidade
Agency
suitable for USP L3
linha de produto
Ascentis®
Características
endcapped: no
embalagem
pkg of 3 ea
técnica(s)
HPLC: suitable
LC/MS: suitable
C × D.I.
5 mm × 3 mm
área da superfície
90 m2/g
Matriz
superficially porous particle
Grupo ativo da matriz
silica phase
tamanho de partícula
5 μm
tamanho de poro
90 Å
pH operacional
1-8
aplicação(ões)
food and beverages
técnica de separação
hydrophilic interaction (HILIC)
normal phase
Procurando produtos similares? Visita Guia de comparação de produtos
Categorias relacionadas
Descrição geral
Informações legais
necessário, mas não fornecido
Código de classe de armazenamento
11 - Combustible Solids
Classe de risco de água (WGK)
WGK 3
Ponto de fulgor (°F)
Not applicable
Ponto de fulgor (°C)
Not applicable
Escolha uma das versões mais recentes:
Certificados de análise (COA)
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.
Se precisar de ajuda, entre em contato Atendimento ao cliente
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
-
What is the Department of Transportation shipping information for this product?
1 answer-
Helpful?
-
-
What steps should be taken to maximize column life?
1 answer-
To maximize column life, ensure that samples and mobile phases are particle-free. The use of guard columns or an in-line filter with 0.5 μm porosity between the sample injector and the column is highly recommended. The 2 μm porosity frits on Ascentis Express 5 μm HILIC columns are less subject to pluggage than are the 0.5 μm frits typically used with other small-particle columns. Should the operating pressure of the column suddenly increase beyond normal levels, reversing the flow direction of the column may be attempted to remove debris on the inlet frit.
Helpful?
-