24031
SPB®-1 Capillary GC Column
L × I.D. 60 m × 0.25 mm, df 1.00 μm
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Materiais
fused silica
Agency
meets requirements for USP G1, G2, and G9
Parâmetros
-60-320 °C temperature (isothermal or programmed)
Valor beta
63
df
1.00 μm
técnica(s)
gas chromatography (GC): suitable
C × D.I.
60 m × 0.25 mm
Grupo ativo da matriz
Bonded; poly(dimethyl siloxane) phase
tipo de coluna
capillary non-polar
Procurando produtos similares? Visita Guia de comparação de produtos
Descrição geral
Capillary GC column is also known as open tubular column. The carrier gas flows through the central aperture and is unrestricted throughout the length of the column.
Application: This column is often used for traditional general purpose applications, where a non-polar column is required. Analytes will be separated primarily according to boiling point.
USP Code: This column meets USP G1, G2, and G9 requirements.
Phase:
USP Code: This column meets USP G1, G2, and G9 requirements.
Phase:
- Bonded
- Poly(dimethyl siloxane)
- ≤0.32 mm I.D., <2 μm: -60 °C to 320 °C (isothermal or programmed)
- ≤0.32 mm I.D., ≥2 μm: -60 °C to 300 °C (isothermal or programmed)
- ≥0.53 mm I.D., <2 μm: -60 °C to 300 °C (isothermal) or 320 °C (programmed)
- ≥0.53 mm I.D., ≥2 μm: -60 °C to 260 °C (isothermal) or 280 °C (programmed)
Aplicação
SPB®-1 Capillary GC Column was used for speciation of the nitrogen compounds (quantitatively), which are polar and somewhat basic in nature, with chemiluminescence detection.
Outras notas
We offer a variety of chromatography accessories including analytical syringes
Informações legais
SPB is a registered trademark of Merck KGaA, Darmstadt, Germany
Escolha uma das versões mais recentes:
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Environmental pollution (Barking, Essex : 1987), 81(2), 179-184 (1993-01-01)
Five Pseudomonad strains, SPb-1, SPb-2, SPb-3, (from a water sample), SPb-4, and SPb-5 (from rhizosphere), which could tolerate lead acetate up to 1000 microm ml(-1), were isolated from an industrially polluted area around Kasoor, Pakistan. Only SPb-5 harbours a lead-resistant
Speciation of nitrogen compounds in gasoline and diesel range process streams by capillary column gas chromatography with chemiluminescence detection.
Journal of Chromatographic Science, 35 (3), 97-104 (1997)
Introduction to Analytical Gas Chromatography, 101-102 (1997)
Chromatograms
suitable for GCsuitable for GC, application for air monitoringNossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica