The protocol for cell samples using MAK434 is as follows:
- Suspend about two million (2 × 10^6) harvested cells in 400 μL PBS on ice. Lysis can be achieved by homogenization (10-20 passes in a Dounce homogenizer on ice) or by sonication (preferably performed in an ice-water bath). The degree of cell lysis can be checked under a microscope. Centrifuge the homogenate at 14,000 g for 10 min and transfer the clear supernatant into a clean tube. It is advisable to run a pilot test of the sample at different dilutions and select a dilution with readings in the linear range of the standard curve for further assays. Most samples can be stored at -80°C if not assayed immediately.
- If a lysis buffer is to be used, it is recommended to first run an assay to test if components in the lysis buffer interfere with the assay. This can be accomplished by running two standard curves: one prepared in H2O and one prepared in the same proportion of lysis buffer that the sample will contain. If the two standard curves are the same, there is no interference and it is safe to use the lysis buffer. If there is a difference in the standard curves, the lysis buffer may still be used if the standard curve remains linear; however, the standard curve to be used for analyzing the lysate samples will need to be prepared in the lysis buffer.
MAK434
Acetaldehyde Assay Kit
Sufficient for 100 colorimetric tests
Selecione um tamanho
Selecione um tamanho
About This Item
Produtos recomendados
Nível de qualidade
entrada
cell culture medium
tissue
serum
urine
food(s)
beverage(s)
plasma
aplicação(ões)
agriculture
cosmetics
environmental
food and beverages
método de detecção
colorimetric
doença(s) relevante(s)
gastrointestinal diseases
temperatura de armazenamento
−20°C
Descrição geral
Aplicação
- Alcohol Metabolism Research
- Hepatology Research
- Neurological Research
Características e benefícios
- Simplified Process: Enjoy a hassle-free procedure that requires the addition of a single working reagent and only a 30 minute assay room temperature reaction, saving you time and effort.
- Convenient and Sensitive: Uses only 20 µL of sample for the determination of acetaldehyde with a detection range of 2 µM to 2mM.
- High-Throughput Compatibility: Seamlessly integrate our kit into high-throughput handling systems, ensuring efficiency and accuracy.
Adequação
Princípio
Outras notas
Palavra indicadora
Warning
Frases de perigo
Declarações de precaução
Classificações de perigo
Eye Irrit. 2 - Skin Irrit. 2
Código de classe de armazenamento
12 - Non Combustible Liquids
Escolha uma das versões mais recentes:
Certificados de análise (COA)
Não está vendo a versão correta?
Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
-
How should MAK434 be used for cell samples?
1 answer-
Helpful?
-
Active Filters
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica