Pular para o conteúdo
Merck
Todas as fotos(3)

Documentos Principais

MAK055

Sigma-Aldrich

AST Activity Assay Kit

sufficient for 100 colorimetric tests

Sinônimo(s):

Aspartate Aminotransferase Activity Assay Kit, Glutamate-Oxaloacetate Transaminase Activity Assay Kit, SGOT Activity Assay Kit, Serum Glutamate-Oxaloacetate Transaminase Activity Assay Kit

Faça loginpara ver os preços organizacionais e de contrato

Selecione um tamanho

1 KIT
R$ 3.461,00

R$ 3.461,00


Em estoqueDetalhes


Solicite uma grande encomenda

Selecione um tamanho

Alterar visualização
1 KIT
R$ 3.461,00

About This Item

Código UNSPSC:
12161503
NACRES:
NA.84

R$ 3.461,00


Em estoqueDetalhes


Solicite uma grande encomenda

uso

sufficient for 100 colorimetric tests

método de detecção

colorimetric

doença(s) relevante(s)

gastrointestinal diseases; cardiovascular diseases

temperatura de armazenamento

−20°C

Informações sobre genes

human ... GOT1(2805)
mouse ... GOT1(14718)
rat ... GOT1(24401)

Categorias relacionadas

Descrição geral

The new AST Assay Kit, MAK467, is now available! Aspartate Aminotransferase (AST), formerly called serum glutamate-oxaloacetate transaminase (SGOT), is a pyridoxal phosphate (PLP)-dependent enzyme that catalyzes the conversion of aspartate and α-ketoglutarate to oxaloacetate and glutamate. Similar to Alanine Aminotransferase (ALT), AST levels in blood are commonly used as a marker for liver function. However, AST has a broader tissue distribution than ALT and perturbations in AST levels can occur in response to diseases or injuries in multiple tissues including skeletal and heart.

Aplicação

AST Activity Assay Kit has been used to determine the activity of aspartate aminotransferase in samples.[1][2]

Características e benefícios

Compatible with high-throughput handling systems.

Adequação

Suitable for the measurement of aspartate aminotransferase (AST) activity in biological samples including tissue, cells and serum

Princípio

The Aspartate Aminotransferase Activity Assay kit provides a simple and direct procedure for measuring AST activity in a variety of samples. In this kit, the transfer of an amino group from aspartate to α-ketoglutarate results in the generation of glutamate, resulting in the production of a colorimetric (450 nm) product proportional to the AST enzymatic activity present. One unit of AST is the amount of enzyme that will generate 1.0 μmole of glutamate per minute at pH 8.0 at 37 °C.

substituído por

Pictogramas

Health hazardCorrosion

Palavra indicadora

Danger

Frases de perigo

Classificações de perigo

Eye Dam. 1 - Resp. Sens. 1 - Skin Corr. 1B

Código de classe de armazenamento

8A - Combustible corrosive hazardous materials


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

Slide 1 of 1

1 of 1

AST487 ≥98% (HPLC)

Sigma-Aldrich

SML2363

AST487

Zhiqiang Ye et al.
Journal of cellular biochemistry, 119(9), 7397-7405 (2018-05-19)
Liver ischemia/reperfusion (I/R) injury has high mortality due to the intense inflammatory process occurs in the liver. However, the pathological mechanism underlying I/R injury is still not clear. Recent works showed that circular RNAs play critical roles in many human
Resolvin D1 and E1 alleviate the progress of hepatitis toward liver cancer in long-term concanavalin A-induced mice through inhibition of NF-KB activity.
Kuang H, et al.
Oncology Reports, 35, 307-317 (2016)
Leola N Chow et al.
PloS one, 11(3), e0151765-e0151765 (2016-03-22)
Modulation of chemokine CXCL12 and its receptor CXCR4 has been implicated in attenuation of bleomycin (BLM)-induced pulmonary fibrosis and carbon tetrachloride (CCl4)-induced hepatic injury. In pulmonary fibrosis, published reports suggest that collagen production in the injured lung is derived from
Tiffany A Katz et al.
Environmental health perspectives, 128(1), 17010-17010 (2020-01-16)
Tributyltin (TBT) is a persistent and bioaccumulative environmental toxicant. Developmental exposure to TBT has been shown to cause fatty liver disease (steatosis), as well as increased adiposity in many species, leading to its characterization as an obesogen. We aimed to
Xiaohuang Lin et al.
Genomics, proteomics & bioinformatics, 18(3), 289-304 (2020-11-02)
Protein lysine methylation is a prevalent post-translational modification (PTM) and plays critical roles in all domains of life. However, its extent and function in photosynthetic organisms are still largely unknown. Cyanobacteria are a large group of prokaryotes that carry out

Questions

1–5 of 5 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. Is it possible to use the MAK055 for an experiment that involves evaluating samples with and without B6 added? Additionally, will hemoglobin interfere if a blood hemolysate sample is used when assayed with this kit?

    1 answer
    1. The specific experiment in question has not been performed in the lab, and there are no references for the Aspartate Aminotransferase Activity Assay Kit where a similar experiment has been reported. Considering the nature of the assay and the fact that B6 is a co-enzyme of the ASP, necessary for its activity, in principle, the kit will be suitable to evaluate samples treated with B6. It will be necessary to evaluate any possible interferences and optimize user-specific conditions.
      It is possible that hemoglobin will interfere with the assay if hemolyzed blood is tested. Blood is generally not recommended as a sample, unless specifically mentioned in the assay, due to the possible interference as mentioned. Furthermore, the kit has not been tested with blood samples.

      Helpful?

  4. Does the AST Activity Assay Kit (MAK055), which includes a positive control (MAK055F), have a specific species origin? For instance, is it Human AST?

    1 answer
    1. The positive control in MAK055 is derived from porcine heart.

      Helpful?

  5. Do you anticipate phenol red in culture medium having an impact on the colorimetric read out at 450 nm? (I'm thinking there may be some spectral overlap)

    1 answer
    1. Ideally, culture media should be phenol red-free.

      Helpful?

Reviews

No rating value

Active Filters

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica