The Rat Stress Hormone panel was tested with 8 mouse samples (2 each of OB/OB, DB/DB, Swiss Webster, and CD-1), and the analytes in the samples tested were successfully detected. However, it's important to note that the assay conditions were not fully validated or optimized for mice. Therefore, the assay need to be validated specifically for mouse samples.
RSHMAG-69K
MILLIPLEX® Rat Stress Hormone Magnetic Bead Panel - Endocrine Multiplex Assay
This MILLIPLEX MAP Rat Stress Hormone Magnetic Bead Panel is an Endocrine multiplex assay. The analytes available for this multiplex kit are: ACTH, Corticosterone, Melatonin.
About This Item
Produtos recomendados
Nível de qualidade
reatividade de espécies
rat
fabricante/nome comercial
Milliplex®
assay range
accuracy: 61%
(Corticosterone)
accuracy: 83%
(ACTH)
sensitivity: 0.9 pg/mL
(ACTH)
sensitivity: 1.52 pg/mL
(Melatonin)
sensitivity: 2914 pg/mL
(Corticosterone)
standard curve range: 0.55-400 pg/mL
(Melatonin)
standard curve range: 1.4-1,000 pg/mL
(ACTH)
standard curve range: 686-500,000 pg/mL
(Corticosterone)
inter-assay cv: <15%
intra-assay cv: <10%
técnica(s)
multiplexing: suitable
método de detecção
fluorometric (Luminex xMAP)
Condições de expedição
wet ice
Descrição geral
MILLIPLEX® Rat Stress Hormone Panel is a 3-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma, tissue/cell extracts or culture media samples: ACTH, corticosterone and/or melatonin. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Endocrine
Especificidade
This assay display insignificant cross-reactivity within the panel
Aplicação
- Analytes: ACTH, Corticosterone, Melatonin
- Recommended Sample Type: Rat serum, plasma, cell/tissue supernatants and lysates
- NOTE: For optimal assay performance of turbid serum and plasma samples an extraction protocol is provided.
- Recommended Sample Dilution: 25μL per well is used for the following: undiluted extracted serum or plasma; 1:4 non-extracted serum or plasma; cell/tissue culture samples may require dilution in an appropriate control medium.
- Assay Run Time: Overnight (16-18 hours) at 2-8°C
- Research Category: Endocrine
- Research Subcategory: Metabolism
Características e benefícios
Outras notas
Informações legais
Exoneração de responsabilidade
Palavra indicadora
Danger
Frases de perigo
Declarações de precaução
Classificações de perigo
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1
Código de classe de armazenamento
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Conteúdo relacionado
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
-
Is it possible to use the Milliplex Rat Stress Hormone Panel (RSHMAG-69K) to detect hormones in mouse samples?
1 answer-
Helpful?
-
Active Filters
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica