CHVE72HS3

Millipore

Millipore Express® SHRP High Area, Cartridge

with prefilter, cartridge nominal length 20 in. (50 cm), filter diam. 2.7 in. (6.9 cm), Code 7

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
23151806

Materiais

polypropylene support
silicone seal

Nível de qualidade

conformidade reg.

meets FDA 21 CFR 177-182 (all component materials)

esterilidade

non-sterile

Compatibilidade de esterilização

autoclavable compatible
steam-in-place compatible

linha de produto

Millipore Express®

Características

hydrophilic
with prefilter

fabricante/nome comercial

Millipore Express®

Parâmetros

≤108.4 mL/min air diffusion at 3.45 bar (50 psig) (in water)
1700 mbar max. differential pressure (25 psi) at 80 °C (Forward)
1700 mbar max. inlet pressure (25 psi) at 80 °C (Forward)
2100 mbar max. inlet pressure (30 psi) at 25 °C (Reverse)
340 mbar max. differential pressure (5 psi) at 135 °C (Forward)
340 mbar max. inlet pressure (5 psi) at 135 °C (Forward)
69 mbar max. inlet pressure (1 psi) at 135 °C (Reverse)
6900 mbar max. differential pressure (100 psi) at 25 °C (Forward)
6900 mbar max. inlet pressure (100 psi) at 25 °C (Forward)

técnica(s)

sterile filtration: suitable

Comprimento

20 in.

Largura

2.8 in.

comprimento nominal do cartucho

20 in. (50 cm)

diâmetro do filtro

2.7 in. (6.9 cm)

filter filtration area

2.0 m2

tamanho do filtro

20 in.

Impurezas

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

matriz

Millipore Express® SHR (w/Prefilter High Area)

pore size

0.5/0.1 μm pore size

ponto de bolha

≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water

código do cartucho

Code 7

Procurando produtos similares? Visita Guia de comparação de produtos

Categorias relacionadas

Descrição geral

Cartridge Type: Liquid
Device Configuration: Cartridge

Embalagem

Double Easy-Open bag

Nota de preparo

Sterilization Method: 5 autoclave cycles of 60 min at 126 °C or 5 forward SIP cycles of 30 min at 135 °C

This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Nota de análise

After sterilization and a controlled water flush of 40 L, samples exhibited <500 ppb TOC per USP 643 and <1.3 μS/cm per USP 645 at 25 °C.

Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.

Outras notas

Directions for Use
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
  • Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Informações legais

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany

Não está encontrando o produto certo?  

Experimente o nosso Ferramenta de seleção de produtos.


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica