Pular para o conteúdo
Merck
Todas as fotos(2)

Documentos

GF88601531

Gadolinium

rod, 100mm, diameter 3.0mm, cast, 99%

Sinônimo(s):

Gadolinium, GD007905

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula linear:
Gd
Número CAS:
Peso molecular:
157.25
Número MDL:
Código UNSPSC:
12141605
ID de substância PubChem:
NACRES:
NA.23

Ensaio

≥99%

forma

rod

fabricante/nome comercial

Goodfellow 886-015-31

resistividade

126 μΩ-cm, 20°C

pb

3273 °C (lit.)

pf

1313 °C (lit.)

densidade

7.886 g/mL at 25 °C (lit.)

cadeia de caracteres SMILES

[Gd]

InChI

1S/Gd

chave InChI

UIWYJDYFSGRHKR-UHFFFAOYSA-N

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

For updated SDS information please visit www.goodfellow.com.

Informações legais

Product of Goodfellow

Pictogramas

Flame

Palavra indicadora

Warning

Frases de perigo

Declarações de precaução

Classificações de perigo

Water-react 3

Código de classe de armazenamento

4.3 - Hazardous materials which set free flammable gases upon contact with water

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Kanae Kawai Miyake et al.
AJR. American journal of roentgenology, 203(2), 272-279 (2014-07-24)
The purpose of this study was to assess the diagnostic value of (18)F-FDG PET/CT and MRI in predicting the clinicopathologic subtypes of breast cancer. The cases of 89 patients with mass-type invasive breast cancer who underwent FDG PET/CT and MRI
Brigit den Adel et al.
Atherosclerosis, 225(2), 274-280 (2012-08-14)
MRI using targeted contrast agents (CA) has emerged as a promising technique to study atherothrombotic disease in vivo. Particularly, the use of targeted Gd and lipid-based nanoparticles has enabled detailed in vivo imaging of various molecular markers of atherosclerotic plaque
Tevfik F Ismail et al.
Heart (British Cardiac Society), 100(23), 1851-1858 (2014-06-27)
Myocardial fibrosis identified by late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) in patients with hypertrophic cardiomyopathy (HCM) is associated with adverse cardiovascular events, but its value as an independent risk factor for sudden cardiac death (SCD) is unknown. We
Giovanni Antonini et al.
Pain, 155(8), 1464-1471 (2014-05-03)
Although classical trigeminal neuralgia (CTN) is frequently caused by neurovascular contact (NVC) at the trigeminal root entry zone (REZ), both anatomical and MRI studies have shown that NVC of the trigeminal nerve frequently occurs in individuals without CTN. To assess
Joana Ramalho et al.
Radiology, 276(3), 836-844 (2015-06-17)
To determine if a correlation exists between the number of previous enhanced magnetic resonance (MR) imaging examinations and high signal intensity in the globus pallidus (GP) and dentate nucleus (DN) in patients who received gadodiamide (Omniscan), a linear nonionic gadolinium-based

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica