Pular para o conteúdo
Merck
Todas as fotos(2)

Key Documents

GF80339205

Silver

foil, 1m coil, thickness 0.05mm, annealed, 99.95+%

Sinônimo(s):

Silver, AG000305

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula linear:
Ag
Número CAS:
Peso molecular:
107.87
Número MDL:
Código UNSPSC:
12141740
ID de substância PubChem:
NACRES:
NA.23

Ensaio

99.95%

forma

foil

fabricante/nome comercial

Goodfellow 803-392-05

resistividade

1.59 μΩ-cm, 20°C

C × espessura

1 m × 0.05 mm

pb

2212 °C (lit.)

pf

960 °C (lit.)

densidade

10.49 g/cm3 (lit.)

cadeia de caracteres SMILES

[Ag]

InChI

1S/Ag

chave InChI

BQCADISMDOOEFD-UHFFFAOYSA-N

Categorias relacionadas

Descrição geral

For updated SDS information please visit www.goodfellow.com.

Informações legais

Product of Goodfellow

Código de classe de armazenamento

13 - Non Combustible Solids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Lamentamos, não temos COA para este produto disponíveis online no momento.

Se precisar de ajuda, entre em contato Atendimento ao cliente

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Clinical evaluation of C-Film, a vaginal contraceptive.
O Frankman et al.
The Journal of international medical research, 3(4), 292-296 (1975-01-01)
IX. Note on Silver Foil in Surgery.
J S Lewis
Annals of surgery, 50(4), 793-796 (1909-10-01)
Zhiping Zhuang et al.
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy, 67(2), 509-516 (2006-09-22)
The molecular geometry and vibrational frequencies of 4,4'-bipyridine (BPE) in the ground state were calculated using density functional theory (DFT) methods (B3LYP) with 6-31++G(d,p) basis set. The optimized geometric bond lengths and bond angles are obtained by DFT employing the
Ken-ichiro Matsumoto et al.
Biological & pharmaceutical bulletin, 28(11), 2029-2034 (2005-11-08)
A novel screening experiment, to find radioactive probes for non-invasive measurements of physiological functions in experimental animals, was tested using the in vivo multitracer analysis technique. The details of the efficiency of the detector settings used in the in vivo
R D Stickrod et al.
Rapid communications in mass spectrometry : RCM, 14(14), 1266-1268 (2000-08-05)
Nitrate-delta(15)N from groundwater samples is determined on an inorganic nitrate derivative using automated, continuous-flow elemental analyzer/isotope ratio mass spectrometry (EA/IRMS). Nitrate is extracted and concentrated based on a recently published ion-exchange resin method. Freeze-dried AgNO(3) (0.5-1.5 mg) is packed in

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica