Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

752460

Sigma-Aldrich

Poly(ethylene glycol) diamine

average MN 10,000, cross-linking reagent carboxyl reactive, amine

Sinônimo(s):

Poly(ethylene glycol) bis(amine), Polyethylene glycol, O,O′-Bis(2-aminoethyl)polyethylene glycol, Diaminopolyethylene glycol, PEG-diamine, Polyoxyethylene bis(amine)

Faça loginpara ver os preços organizacionais e de contrato

Selecione um tamanho

1 G
R$ 748,00
5 G
R$ 2.838,00

R$ 748,00


Previsão de entrega em24 de maio de 2025


Solicite uma grande encomenda

Selecione um tamanho

Alterar visualização
1 G
R$ 748,00
5 G
R$ 2.838,00

About This Item

Fórmula linear:
H2N(CH2CH2O)nCH2CH2NH2
Número CAS:
Número MDL:
Código UNSPSC:
12162002
NACRES:
NA.23

R$ 748,00


Previsão de entrega em24 de maio de 2025


Solicite uma grande encomenda

Nome do produto

Poly(ethylene glycol) diamine, average Mn 10,000

Formulário

powder or solid (or chunk(s))

peso molecular

average Mn 10,000

adequação da reação

reagent type: cross-linking reagent
reactivity: carboxyl reactive

pf

56-60 °C

Ω-final

amine

α-final

amine

arquitetura do polímero

shape: linear
functionality: homobifunctional

cadeia de caracteres SMILES

NCCOCCOCCN

InChI

1S/C6H16N2O2/c7-1-3-9-5-6-10-4-2-8/h1-8H2

chave InChI

IWBOPFCKHIJFMS-UHFFFAOYSA-N

Procurando produtos similares? Visita Guia de comparação de produtos

Aplicação

Polymer for preparing enzyme conjugates soluble in organic solvents†; promising drug carrier†

Código de classe de armazenamento

10 - Combustible liquids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Malar A. Azagarsamy, et al.
Material Matters, 7 (2012)
Stephen J Connon et al.
Bioorganic & medicinal chemistry letters, 12(14), 1873-1876 (2002-06-28)
The synthesis and olefin metathesis activity in protic solvents of 7, a phosphine-free ruthenium alkylidene bound to a hydrophilic solid support are reported. This heterogeneous catalyst promotes relatively efficient ring closing- and cross-metathesis reactions in both methanol and water. The
Gaëlle-Anne Cremer et al.
Journal of peptide science : an official publication of the European Peptide Society, 12(6), 437-442 (2006-01-25)
This paper describes the optimization of a synthesis of a difficult sequence related to a 12-mer sequence of a Pan DR epitope (PADRE). Elongation was followed by on-line monitoring of the N(alpha)-Fmoc removal adapted for the batch methodology. Studying the
Alison G Patrick et al.
Macromolecular bioscience, 10(10), 1184-1193 (2010-07-02)
The design of hydrogels that simultaneously report protease activity and remove excess protease from solution is elucidated. The hydrogels, based on amino-PEGA, combine enzyme-specific peptides flanked with FRET complimented by charged amino acid residues that facilitate protease uptake via short
Emmanuelle Bays et al.
Biomacromolecules, 10(7), 1777-1781 (2009-06-10)
Maleimide end functionalized polymers for site-selective conjugation to free cysteines of proteins were synthesized using reversible addition-fragmentation chain transfer (RAFT) polymerization. A furan-protected maleimide chain transfer agent (CTA) was employed in the RAFT polymerization of poly(ethylene glycol) methyl ether acrylate

Artigos

Hydrogel-based biomaterials for cell delivery and tissue regeneration applications are discussed.

Questions

Reviews

No rating value

Active Filters

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica