Accéder au contenu
Merck
Toutes les photos(1)

Documents

46947

Sigma-Aldrich

Fluorescein isothiocyanate – Dextran 500000-Conjugate

(FITC:Glucose = 1:100)

Synonyme(s) :

Dextran 500′000 Fluorescein isothiocyanate Conjugate

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12352108
Nomenclature NACRES :
NA.32

Forme

powder or crystals

Composition

(FITC:Glucose = 1:100)

Ampleur du marquage

0.01 mol/mol FITC glucose (substitution)

Technique(s)

permeability assay: suitable

Solubilité

H2O: 25 mg/mL, clear to very faintly turbid, yellow to orange

Fluorescence

λex 490 nm; λem 520 nm (pH 8.0)

Température de stockage

2-8°C

Application

Fluorescein isothiocyanate – Dextran 500000-Conjugate is used as a fluorescent tissue permeability assay reagent and as a diffusion probe for evaluation of biomaterials such as hydrogels and lipid vesicles.

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

Eyeshields, Gloves, type N95 (US)


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Joel Hagman et al.
Biomacromolecules, 11(12), 3359-3366 (2010-11-09)
The time-dependent diffusion and mechanical properties of gelatin in solution, in the gel state, and during the sol/gel transition were determined using fluorescence recovery after photobleaching (FRAP) and rheology. The parameters in the experimental design were 2% w/w and 5%
Ayesha Chaudhary et al.
Biotechnology and bioengineering, 104(6), 1075-1085 (2009-08-06)
The feasibility of dissolved-core alginate-templated fluorescent microspheres as "smart tattoo" glucose biosensors was investigated in simulated interstitial fluid (SIF). The sensor works on the principle of competitive binding and fluorescence resonance energy transfer. The sensor consists of multilayer thin film
Tina Vermonden et al.
Macromolecules, 43(2), 782-789 (2010-10-05)
Hydrogel formation triggered by a change in temperature is an attractive mechanism for in situ gelling biomaterials for pharmaceutical applications such as the delivery of therapeutic proteins. In this study, hydrogels were prepared from ABA triblock polymers having thermosensitive poly(N-(2-hydroxypropyl)
Lisa M Dominak et al.
Langmuir : the ACS journal of surfaces and colloids, 24(23), 13565-13571 (2008-11-05)
We report the effect of macromolecular crowding on encapsulation efficiency of fluorescently labeled poly(ethylene glycol) (PEG) and dextran polymers within individual giant lipid vesicles (GVs). Low concentrations of the fluorescently labeled polymers (82 nM to 186 pM) were mixed with
Woo Jin Kim et al.
ACS nano, 14(10), 13217-13231 (2020-09-25)
Male infertility is a multifactorial condition. Unexplained male infertility is often caused by spermatogenesis dysfunction. Knockout of Pin1, an important regulator of cell proliferation and differentiation, produces male infertility phenotypes such as testicular immaturity and azoospermia with spermatogonia depletion and

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique