Direkt zum Inhalt
Merck
  • Simultaneous tissue profiling of eicosanoid and endocannabinoid lipid families in a rat model of osteoarthritis.

Simultaneous tissue profiling of eicosanoid and endocannabinoid lipid families in a rat model of osteoarthritis.

Journal of lipid research (2014-07-27)
Amy Wong, Devi R Sagar, Catharine A Ortori, David A Kendall, Victoria Chapman, David A Barrett
ZUSAMMENFASSUNG

We describe a novel LC method for the simultaneous and quantitative profiling of 43 oxylipins including eicosanoids, endocannabinoids, and structurally related bioactive lipids with modified acyl groups. The LC-MS/MS method uses switching at a defined time between negative and positive electrospray ionization modes to achieve optimal detection sensitivity for all the lipids. The validated method is linear over a range of 0.01-5 nmol/g (0.1-50 nmol/g for 2-arachidonoyl glycerol) with intra- and interday precision and accuracy between 1.38 and 26.76% and 85.22 and 114.3%, respectively. The method successfully quantified bioactive lipids in different tissue types in the rat, including spinal cord, dorsal root ganglia (DRGs), knee joint, brain, and plasma. Distinct regional differences in the pattern of lipid measured between tissue types were observed using principle component analysis. The method was applied to analyze tissue samples from an established preclinical rat model of osteoarthritis (OA) pain and showed that levels of 12-hydroxyeicosatetraenoic acid were significantly increased in the OA rat knee joint compared with controls, and that 15-hydroxyeicosatetraenoic acid was significantly increased in the DRGs in the model of OA compared with controls. The developed LC-MS/MS method has the potential to provide detailed pathway profiling in tissues and biofluids where the disruption of bioactive oxylipins may be involved in disease states.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Acetonitril, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, for molecular biology
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethylacetat, ACS reagent, ≥99.5%
Sigma-Aldrich
Ammoniumhydroxid -Lösung, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Acetonitril, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ethylacetat, suitable for HPLC, ≥99.7%
Sigma-Aldrich
Ameisensäure, reagent grade, ≥95%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ethylacetat, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Ameisensäure, ACS reagent, ≥96%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, meets USP testing specifications
Sigma-Aldrich
Hexan, ReagentPlus®, ≥99%
Sigma-Aldrich
Hexan, suitable for HPLC, ≥95%
Sigma-Aldrich
Ammoniumhydroxid -Lösung, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
Acetonitril, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, for molecular biology
Sigma-Aldrich
Acetonitril, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Hexan, Laboratory Reagent, ≥95%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Hexan, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
Acetonitril, anhydrous, 99.8%
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Ameisensäure, ACS reagent, ≥88%
Sigma-Aldrich
Ethylacetat, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, Absolute - Acetone free
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%