Direkt zum Inhalt
Merck

Fortfahren mit

24634

10 l Tedlar® PLV-Gasentnahmebeutel mit Thermogreen® LB-2 Septen

maximum volume 10 L, Push/Pull Lock Valve (PLV) (Push Lock Valve (PLV))

Synonym(e):

Tedlar® Gasprobenahmebeutel

Anmelden zur Ansicht der Organisations- und Vertragspreise.

Größe auswählen

Ansicht ändern
Größe/SKUVerfügbarkeitPreis

Über diesen Artikel

UNSPSC Code:
41104008
NACRES:
NB.21
Preise und Verfügbarkeit sind derzeit nicht verfügbar.
Technischer Dienst
Benötigen Sie Hilfe? Unser Team von erfahrenen Wissenschaftlern ist für Sie da.
Unterstützung erhalten


material

Tedlar® PVDF film

Quality Segment

agency

suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC), suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC), suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs)), suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC)), suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS), suitable for NIOSH 3704 (Perchloroethylene)

description

septum type: yes; Thermogreen® LB-2

packaging

pkg of 10 bags

technique(s)

whole air sampling: suitable

W × L

12 in. × 19 in.

maximum volume

10 L

application(s)

air monitoring
environmental
industrial hygiene

compatibility

for use with Calibration mixes - gas phase standards/gas mixtures

General description

Tedlar-Beutel eignen sich für die Aufbewahrung und den Transport der zu untersuchenden Gasproben. Sie bestehen aus einem Polyvinylfluorid-Film.
Tedlar wird für mehrere U.S. EPA-Methoden zur Probenahme von flüchtigen organischen Verbindungen und Schwefelverbindungen empfohlen. Unser Tedlar besteht aus einer hochwertigen 2-mil-Tedlar-Folie für hervorragende Reaktionsträgheit, Dichtheit, Probenintegrität und gute Rückgewinnungsdaten. Unser Verriegelungsventil (PLV) und Nahtversiegelungsprozess sorgen dafür, dass diese Beutel selbst unter den herausforderndsten Probenahme- und Versandbedingungen strapazierfähig und nahezu dicht sind.

Application

Tedlar-Beutel (10 L) eignen sich zur Sammlung landwirtschaftlicher Geruchsstoffe, um das Sorptionsverhalten der wichtigsten Geruchsstoffe mittels Gaschromatographie-Massenspektrometrie/Olfaktometrie (GC-MS-O) zu messen.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Tedlar is a registered trademark of E. I. du Pont de Nemours and Company
Thermogreen is a registered trademark of Merck KGaA, Darmstadt, Germany

Ähnliche Artikel vergleichen

Vollständigen Vergleich anzeigen

Unterschiede anzeigen

1 of 1

Dieser Artikel
246542463324655
description

maximum volume 10 L, Push/Pull Lock Valve (PLV) (Push Lock Valve (PLV))

description

-

description

Push/Pull Lock Valve (PLV)

description

-

material

Tedlar® PVDF film

material

Tedlar® PVDF film

material

Tedlar® PVDF film

material

Tedlar® PVDF film

agency

suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC), suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS), suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC), suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC)), suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs)), suitable for NIOSH 3704 (Perchloroethylene)

agency

suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC), suitable for NIOSH 3704 (Perchloroethylene), suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs)), suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC), suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC)), suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS)

agency

suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC)), suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs)), suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC), suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC), suitable for NIOSH 3704 (Perchloroethylene), suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS)

agency

suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC), suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs)), suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS), suitable for NIOSH 3704 (Perchloroethylene), suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC), suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC))

technique(s)

whole air sampling: suitable

technique(s)

whole air sampling: suitable

technique(s)

whole air sampling: suitable

technique(s)

whole air sampling: suitable

maximum volume

10 L

maximum volume

2 L

maximum volume

1 L

maximum volume

5 L

description

septum type: yes; Thermogreen® LB-2

description

Push/Pull Lock Valve (PLV) (Push Lock Valve (PLV)), septum type: yes; Thermogreen® LB-2

description

septum type: yes; Thermogreen® LB-2

description

septum type: yes; Thermogreen® LB-2, Push/Pull Lock Valve (PLV) (Push Lock Valve (PLV))

Quality Level

100

Quality Level

100

Quality Level

100

Quality Level

100




Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumente section.

Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen



Questions

Reviews

No rating value

Active Filters