Direkt zum Inhalt
Merck

Fortfahren mit

17810

Triglycerid-Mischung

C2 - C10, ampule of 100 mg (Neat)

Synonym(e):

Lipidstandards: Triglycerid-Mischungen

Anmelden zur Ansicht der Organisations- und Vertragspreise.

Größe auswählen

Ansicht ändern
Größe/SKUVerfügbarkeitPreis
1 amp
Warenkorb auf Verfügbarkeit prüfen
€ 53,70

Über diesen Artikel

NACRES:
NA.24
UNSPSC Code:
85151701

€ 53,70


Warenkorb auf Verfügbarkeit prüfen

​
Sonderanfertigung anfragen
Technischer Dienst
Benötigen Sie Hilfe? Unser Team von erfahrenen Wissenschaftlern ist für Sie da.
Unterstützung erhalten


grade

analytical standard

Quality Segment

form

liquid

CofA

current certificate can be downloaded

packaging

ampule of 100 mg (Neat)

format

multi-component solution

shipped in

dry ice

storage temp.

-10 to -25°C

Application

Triglyceride mix has also been used in a study done to compare the retention time for that of the triacylglycerols; in study to analyse acylglycerols of substrates and products interesterification using GC method.

Packaging

100 mg Ampulle enthält ca. gleiche Gewichtsmengen von:
Triacetin (C2:0)
Tributyrin (C4:0)
Tricaproin (C6:0)
Tricaprylin (C8:0)
Tricaprin (C10:0)

Ähnliche Artikel vergleichen

Vollständigen Vergleich anzeigen

Unterschiede anzeigen

1 of 1

Dieser Artikel
41679CRM47792LM6004
description

C2 - C10, ampule of 100 mg (Neat)

description

analytical standard

description

certified reference material, 10 mg/mL in dichloromethane, ampule of 1 mL

description

Avanti Research™ - A Croda Brand LM6004

form

liquid

form

-

form

liquid

form

solution

format

multi-component solution

format

neat

format

multi-component solution

format

-

Quality Level

100

Quality Level

100

Quality Level

300

Quality Level

-

grade

analytical standard

grade

analytical standard

grade

TraceCERT®, certified reference material

grade

-

storage temp.

-10 to -25°C

storage temp.

−20°C

storage temp.

-10 to -25°C

storage temp.

−20°C

packaging

ampule of 100 mg (Neat)

packaging

-

packaging

ampule of 1 mL

packaging

pkg of 1 × 1 mL (LM6004-1EA)


Lagerklasse

10 - Combustible liquids

wgk

WGK 3

flash_point_f

300.0 °F

flash_point_c

148.9 °C



Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumente section.

Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen



Questions

1–8 of 8 Questions  
  1. Can this be used for interference testing?

    1 answer
    1. This product has not been specifically tested for use in serum interfere studies, but has been used successfully both other researchers.

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  3. Can I use it in cell culture?

    1 answer
    1. This product is not tested for the suitability of cell culture applications. The end-user would be responsible for determining suitability. See the links below to review cell culture tested lipid mixtures that may be of interest.
      L5146
      https://www.sigmaaldrich.com/US/en/product/sigma/l5146
      L0288
      https://www.sigmaaldrich.com/US/en/product/sigma/l0288

      Helpful?

  4. How can I reconstitute, and what is the recommended stock concentration preparation?

    1 answer
    1. This product is not tested for solubility. Lipids are not directly soluble in aqueous solutions. Typically, strong non-polar solvents are used to dissolve these compounds. Hexane has been used in analytical testing of the individual triglycerides. In most liquid chromatography techniques, the solvents utilized are acetone and/or acetonitrile. In gas chromatography, the mixture is derivatized to methyl esters using hexane, ether, or toluene. Pyridine is also a suitable solvent prior to derivatization with MSTFA. During manufacturing, chloroform is commonly used.
      Other suggested intermediate solvents include acetone, ethanol, and dimethylsulfoxide. Please see the link below to review additional information on lipids:
      http://www.cyberlipid.org/

      Helpful?

  5. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  6. Is standard 17810 actually in the amount of 100 mg? Are standards weighed to the exact amount as indicated?

    1 answer
    1. The standard 17810 is not actually in the amount of 100 mg. Both neat (pure) and solution standards are typically weighed or dispensed with approximately 10-15% extra product to allow for accurate measurement of the total amount indicated. Therefore, while it is indicated to have 100mg, there is an extra amount typically added during the weighing and packaging process

      Helpful?

  7. 해당 제품을 50 mg/mL로 희석하여 사용하고자 합니다. 알맞은 용매가 있을까요?

    1 answer
    1. This product is not tested for solubility. Lipids are not directly soluble in aqeuous solutions. Typically, strong non-polar solvents are used to dissolve these compounds. Hexane has been used in analytical testing of the individual triglyderides. In most liquid chromatography techniques the solvents utilized are acetone and/or acetonitrile. In gas chromatography the mixture is derivatized to methyl esters using hexane, ether, or toluene. Pyridine is also a suitable solvent prior to derivatization with MSTFA. During manufacturing, chloroform is commonly used.
      Other suggested intermediate solvents include acetone, ethanol, and dimethylsulfoxide. Please see the link below to review additional information on lipids:
      http://www.cyberlipid.org/

      Helpful?

  8. こちらの製品(17810)のモル濃度と液量が知りたいです

    1 answer
    1. This product is a neat or pure liquid that is sold by weight. Each 100 mg ampule is comprised of approximately 20% of each component:

      Tributyrin, CAS 60-01-5, density 1.032 g/mL, MW 302.36
      Tricaproin, CAS 621-70-5, density 0.98 g/mL, MW 386.52
      Triacetin, CAS 102-76-1, density 1.16 g/mL, MW 218.20
      Tricaprylin, CAS 538-23-8, density 0.956 g/mL, MW 470.68
      Tricaprin CAS 621-71-6, powder, MW 554.84

      The exact volume is not reported, however, based on the densities of the components, a 100 mg package would have a volume of approximately 100 ul.

      Helpful?