Direkt zum Inhalt
Merck

LB1HCG6S2

Millipore

Millistak+® Lentikulärer Scheibenfilter

B1HC, cellulose, filtration area 1.8 m2, hydrophilic

Synonym(e):

Millistak+ Lenticular Disc Filters, B1HC media series, 16 in. diameter, 8-cell, silicone seal, 2/pack

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
23151806
eCl@ss:
32031690

Materialien

cellulose
filter aid (inorganic)
mixed cellulose esters (MCE)
polypropylene
silicone seal

Qualitätsniveau

Beschreibung

Post-centrifuge or settled permeate containing cellular particulate

Leistungsmerkmale

hydrophilic

Hersteller/Markenname

Millistak+®

Parameter

0.03 bar max. differential pressure (0.5 psid) (Reverse)
0.2 bar max. inlet pressure (3 psi) at 123 °C
0.21 bar max. differential pressure (3 psid) at 123 °C (Forward)
1 bar max. inlet pressure (15 psi) at 80 °C
1.03 bar max. differential pressure (15 psid) at 80 °C (Forward)
2.07 bar max. differential pressure (30 psid) at 25 °C (Forward)
2.1 bar max. inlet pressure (30 psi) at 25 °C

Durchmesser

40.64 cm (16 in.)

Filtrationsfläche

1.8 m2

Verunreinigungen

<0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

non-volatile residue (NVR)

1.50-2.02 mg/m2 (gravimetric analysis test)

Rest-TOC (gesamter organischer Kohlenstoff)

416-593 ppb (gravimetric analysis test)
565-1037 ppb

Aufnahme

sample type liquid

Leitfähigkeit

5-7 μmho per cm at 25 °C (product water)

Filterqualität

B1HC

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Device Configuration: Stack Disk
Stack Design: 16 in. diameter, 8-cell

Anwendung

Post-centrifuge or settled permeate containing cellular particulate

Spezifikationen

Filter Grade: B1HC

Angaben zur Herstellung

Sterilization Method
3 In-situ-Dampfsterilisationszyklen von 30 min bei 123 °C
Sanitization Protocol
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes

Hinweis zur Analyse

Gravimetric Extractables: Post autoclave (1 cycle of 30 minutes at 123 °C) and pure water flush of 100 L/m2 (10 L/ft2) of media surface area
Product Water Conductivity at 25°C: after a pure water flush of 10 L/ft2 (100 L/m2) of media surface area per autoclaved (1 cycle of 30 minutes at 123 °C) 12" 16-stack device
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
Total Organic Carbon (TOC) Residue: post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 10 liters per ft2 (100 L/m2) of media surface area

Rechtliche Hinweise

MILLISTAK+ is a registered trademark of Merck KGaA, Darmstadt, Germany

Piktogramme

Health hazard

Signalwort

Danger

H-Sätze

Gefahreneinstufungen

STOT RE 1 Inhalation

Zielorgane

Lungs

Lagerklassenschlüssel

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 3


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.