Saltar al contenido
Merck
Todas las fotos(2)

Documentos clave

S2GPU02RE

Millipore

Sistema de filtración al vacío Millipore® Stericup® Quick Release

Millipore® Stericup® Quick Release Vacuum Filtration System
1 of 3 reviewers received a sample product or took part in a promotion

pore size 0.22 μm, polyethersulfone membrane, funnel capacity 250 mL, pack of 12 ea

Sinónimos:

SCGPU02RE, Sistema de filtración al vacío estéril Stericup Quick Release-GP

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
41104914
eCl@ss:
32031623
NACRES:
NB.24
En este momento no podemos mostrarle ni los precios ni la disponibilidad

material

polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing

Quality Level

sterility

sterile; irradiated

product line

Stericup®

feature

hydrophilic

packaging

pack of 12 ea

parameter

45 °C max. temp.

description

2.4 mL (hold-up volume)

technique(s)

sterile filtration: suitable

H

164 mm

capacity

250 mL

diam.

12.5 cm

filter diam.

73 mm

filtration area

40 cm2

funnel capacity

250 mL

matrix

Express PLUS

pore size

0.22 μm pore size

fitting

inlet funnel
outlet flask (Receiver)

shipped in

ambient

General description

Este artículo es un sustituto directo de SCGPU02RE
Trabaje con facilidad y filtre con confianza con los sistemas de filtración Stericup® y Steritop®.

Las unidades de filtración estériles Stericup® y Steritop® utilizan membranas de alto rendimiento fiables para una esterilización por filtración óptima de los reactivos, las disoluciones tampón y los medios. Estos dispositivos combinan caudales y rendimiento superiores con una baja adsorción inespecífica y un diseño estable sin puntas.

Esta unidad de filtración Stericup® con membrana de polietersulfona (PES) y tamaño de poro de 0,22 μm combina una tapa de botella de 250 ml con un matraz receptor de 250 ml y una tapa para procesamiento y almacenamiento.

Application

Los sistemas Stericup® y Steritop® están diseñados para reducir la formación de espuma y la desnaturalización de las proteínas al tiempo que maximizan el flujo y se pueden utilizar para la esterilización por filtración al vacío de disoluciones acuosas, como medios de cultivo de tejidos y líquidos biológicos.
  • Medios de cultivo de tejidos +/- aditivos
  • Amortiguadores
  • Disoluciones biológicas
Para uso exclusivo en investigación

Features and Benefits

  • El embudo de filtración Quick Release se desconecta de la botella receptora con solo un cuarto de vuelta—reduciendo así la probabilidad de derrame y haciendo que sea más fácil manipularlo sobre la mesa de trabajo o debajo de la campana.
  • La identificación del producto en negrita en el embudo de filtración Steritop® muestra claramente las características de la membrana, como su composición y el tamaño de los poros, una selección de productos rápida y apropiada para la aplicación.
  • El tapón de cierre mediante un clic está bridado y modificado para permitir un fuerte agarre en condiciones secas—y un tope táctil confirma el cierre seguro. Preocúpese menos de la posibilidad de derramamiento o contaminación de los contenidos esterilizados.
  • Una amplia superficie esmerilada de escritura en la botella receptora y el color más claro del tapón facilitan el etiquetado claro para mejorar la legibilidad y reducir los frotis ilegibles.
  • La tapa descansa sobre el lateral para evitar el riesgo de contaminación.
  • Las botellas receptoras son apilables para ahorrar espacio de almacenamiento.

Legal Information

EXPRESS PLUS is a trademark of Merck KGaA, Darmstadt, Germany
Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
Stericup is a registered trademark of Merck KGaA, Darmstadt, Germany

¿No encuentra el producto adecuado?  

Pruebe nuestro Herramienta de selección de productos.


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Artículos

Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.

Contenido relacionado

This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.

Questions

1–10 of 16 Questions  
  1. Buongiorno. I filtri resistono ad inchiostri UV a base acrilica, all'acetone e all'alcool isopropilico?

    1 answer
    1. This product is composed of polyethersulfone and polystyrene materials. Hence, it is not recommended for use with acetone.
      Please see the chemical compatibility chart: https://www.sigmaaldrich.com/technical-documents/technical-article/analytical-chemistry/filtration/chemical-compatibility-of-filter-components?utm_source=redirect&utm_medium=promotional&utm_campaign=FilterChemicalCompatibility

      However, the product's compatibility with acrylic-based UV inks and isopropyl alcohol has not been validated.
      Please see the user guide for more information:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/337/924/20199204w-ms.pdf

      Helpful?

  2. What is the chemical compatibility of the various Stericup® and Steritop® filters?

    1 answer
    1. Please refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf

      Helpful?

  3. Can Stericup® bottles be placed inside freezers for long-term storage of media?

    1 answer
    1. You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.

      Helpful?

  4. Can Stericup® and Steritop® filters be used to prepare solutions that will be administered to patients?

    1 answer
    1. No, all Stericup® and Steritop® devices are Research Use Only.

      Helpful?

  5. What leachables are detected during filtration processes using Stericup® filters?

    1 answer
    1. We have not performed extractables/leachables studies for our Stericup® filters.

      Helpful?

  6. What Bacterial Endotoxins Test is used?

    1 answer
    1. The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.

      Helpful?

  7. The User Guide says “Use only glass or plastic bottles designed for vacuum applications”. Can you specify which bottles are compatible?

    1 answer
    1. Steritop® Quick Release bottle top units require a vacuum-rated receiver bottle with either a GL33 or GL45 mm closure thread as specified. Steritop® E bottle top units require a vacuum-rated receiver bottle with a GL45 mm closure thread. Bottles no larger than 2 L should be used.
      Glass bottles, GL33:
      • Wheaton media bottles (glass), 500 mL (Product Z364886)
      • Wheaton media bottles (glass), 1 L (Product Z364894)
      Glass bottles, GL45
      • Corning® glass media storage bottle, 125 mL (Product CLS1399125)
      • Corning® glass media storage bottle, 250 mL (Product CLS1399250)
      • Corning® glass media storage bottle, 500 mL (Product CLS1399500)
      • Corning® glass media storage bottle, 1 L (Product CLS13991L)
      • Pyrex® round media storage bottle, 500 mL (Product CLS1395500)
      • Pyrex® round media storage bottle, 1 L (Product CLS13951L)
      • KIMBLE® KIMAX® Media bottle, 250 mL (Product DWK14395250)
      • KIMBLE® KIMAX® Media bottle, 500 mL (Product DWK14395500)
      • KIMBLE® KIMAX® Media bottle, 1 L (Product DWK143951000)
      Plastic (pre-sterile) bottles, GL45:
      • Stericup® Quick Release Receiver flask, 250 mL (Product S200B02RE)
      • Stericup® Quick Release Receiver flask, 500 mL (Product S200B05RE)
      • Stericup® Quick Release Receiver flask, 1000 mL (Product S200B10RE)

      Helpful?

  8. What is the difference between classic Stericup® filters and Stericup® “Quick Release” filters?

    1 answer
    1. Stericup® Quick Release, or “QR”, filters feature a connection between funnel filter and receiver bottle that requires only a quarter-turn release to facilitate funnel removal. These filters come fully engaged – there is no need to tighten before use. The receiver bottle cap has flanges on the top surface to improve grip, as well as a positive lock stop to ensure a leak-proof seal with the receiver bottle. Other improvements include a large, frosted writing surface on the receiver bottle and a lighter cap color to facilitate labelling, more prominent volume markings on the filtration funnel and receiver bottle, and a product label with a peel-off lot record strip on the bag for easy viewing in storage.

      Helpful?

  9. What is the maximum vacuum pressure for filtration?

    1 answer
    1. 700 mm Hg (27.5” Hg, 0.9 bar) differential vacuum at 25 °C (77 °F)

      Helpful?

  10. Which type of pump should be used with Stericup® and Steritop® vacuum filters?

    1 answer
    1. We recommend our Chemical Duty Pump: https://www.sigmaaldrich.com/product/mm/wp6111560

      Helpful?

1–10 of 16 Questions  

Reviews

1 of 3 reviewers received a sample product or took part in a promotion

Active Filters

  1. Columbia, MO
    • Reviews 4
    • Votes 0
    5 out of 5 stars.

    Easy to use filter units that work well

    Sigma is known for its high quality of chemical and biochemical reagents, and this is no exception.

    Helpful?

  2. 2 Ratings-Only Reviews

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico