Saltar al contenido
Merck
Todas las fotos(1)

Documentos clave

S2GPT02RE

Millipore

Millipore® Steritop® Filtro de tapa botella al vacío

pore size 0.22 μm, polyethersulfone membrane, funnel capacity 250 mL, pack of 12 ea

Sinónimos:

Filtro de tapa de botella a rosca Steritop, SCGPT02RE

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
41104914
eCl@ss:
32031623
NACRES:
NB.24
En este momento no podemos mostrarle ni los precios ni la disponibilidad

Materiales

polyethersulfone membrane
polystyrene funnel(s)
polystyrene housing

Nivel de calidad

esterilidad

sterile; irradiated

Línea del producto

Steritop®

Características

hydrophilic

envase

pack of 12 ea

Parámetros

45 °C max. temp.

descripción

2.4 mL (hold-up volume)

técnicas

sterile filtration: suitable

Altura

95 mm

capacidad

250 mL

Diámetro

12.5 cm

diám. del filtro

73 mm

filtración área

40 cm2

embudo capacidad

250 mL

Matriz

Express PLUS

tamaño de poro

0.22 μm pore size

Adaptador

inlet funnel
45 mm outlet thread(s)

Condiciones de envío

ambient

Descripción general

Este artículo es un sustituto directo de SCGPT05RE
Trabaje con facilidad y filtre con confianza con los sistemas de filtración Stericup® y Steritop®.

Las unidades de filtración estériles Stericup® y Steritop® utilizan membranas de alto rendimiento fiables para una esterilización por filtración óptima de los reactivos, las disoluciones tampón y los medios. Estos dispositivos combinan caudales y rendimiento superiores con una baja adsorción inespecífica y un diseño estable sin puntas.

Esta tapa de botella Steritop® de 250 ml con una membrana de filtración de polietersulfona (PES) y un tamaño de poro de 0,22 μm puede utilizarse en botellas con aberturas de 45 mm, diseñadas para aplicaciones de vacío.

Aplicación

Los sistemas Stericup® y Steritop® están diseñados para reducir la formación de espuma y la desnaturalización de las proteínas mientras maximizan el flujo y pueden utilizarse para la filtración esterilizante al vacío de disoluciones acuosas como medios de cultivo de tejidos y líquidos biológicos.

  • Medios de cultivo de tejidos +/- aditivos
  • Amortiguadores
  • Disoluciones biológicas
Para uso exclusivo en investigación

Características y beneficios

La identificación del producto en negrita en el embudo de filtración Steritop® muestra claramente las características de la membrana, como su composición y el tamaño de los poros, para la selección del producto apropiado para la aplicación.

Información legal

EXPRESS PLUS is a trademark of Merck KGaA, Darmstadt, Germany
Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
STERITOP is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Artículos

Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.

Contenido relacionado

This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.

Questions

1–10 of 17 Questions  
  1. Can you use filtration units to filter and also degas solutions?

    1 answer
    1. Vacuum filter cups are commonly used in the industry to degas solutions. For some liquid chromatography systems, applying a vacuum while filtering the mobile phase may remove enough gas to prevent issues.

      Helpful?

  2. Can Stericup® bottles be placed inside freezers for long-term storage of media?

    1 answer
    1. You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.

      Helpful?

  3. What Bacterial Endotoxins Test is used?

    1 answer
    1. The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.

      Helpful?

  4. Which type of pump should be used with Stericup® and Steritop® vacuum filters?

    Which type of pump should be used with Stericup® and Steritop® vacuum filters?

    1 answer
    1. We recommend our Chemical Duty Pump: https://www.sigmaaldrich.com/product/mm/wp6111560

      Helpful?

  5. What is the maximum vacuum pressure for filtration?

    1 answer
    1. 700 mm Hg (27.5” Hg, 0.9 bar) differential vacuum at 25 °C (77 °F)

      Helpful?

  6. What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?

    1 answer
    1. All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
      *Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.

      Helpful?

  7. Are Stericup® and Steritop® filters GMP-certified?

    1 answer
    1. No, Stericup® and Steritop® devices are not GMP-approved.

      Helpful?

  8. Can Stericup® and Steritop® filters be reused?

    1 answer
    1. All Stericup® and Steritop® filters were developed for single use, disposable processing.

      Helpful?

  9. Can Stericup® and Steritop® filters be used to prepare solutions that will be administered to patients?

    1 answer
    1. No, all Stericup® and Steritop® devices are Research Use Only.

      Helpful?

  10. What is the expiration date of Stericup® and Steritop® filters?

    1 answer
    1. Typically 3 years from sterilization.

      Helpful?

1–10 of 17 Questions  