Skip to Content
MilliporeSigma

Skip To

773735

Carbon nanotube, single-walled

(6,5) chirality, ≥95% carbon basis (≥95% as carbon nanotubes), 0.78 nm average diameter

Synonym(s):

CHASM, CNT, Signis® SG65i, SWCNT, SWNT, Single wall carbon nanotube

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice
250 mg

Available to ship TODAYfromMILWAUKEE

$518.00
1 g

Available to ship TODAYfromMILWAUKEE

$1,400.00

About This Item

CAS Number:
MDL number:
UNSPSC Code:
12352103
NACRES:
NA.23

$518.00


Available to ship TODAYDetails


Request a Bulk Order
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Level

description

G/D Ratio: ≥20 (Raman 633 nm), Median length: 1 μm

assay

≥95% carbon basis (≥95% as carbon nanotubes)

form

powder (freeze-dried)

manufacturer/tradename

Signis® SG65i

surface area

≥700 m2/g

impurities

≤5 wt. % Moisture content

average diameter

0.78 nm

mp

3652-3697 °C (lit.)

density

1.7-1.9 g/cm3 at 25 °C (lit.)

bulk density

0.1 g/cm3

SMILES string

[C]

InChI

1S/C

InChI key

OKTJSMMVPCPJKN-UHFFFAOYSA-N

General description

Produced using CHASM′s patented CoMoCAT synthesis technology, Signis® SG65i is a single-wall carbon nanotube (CNT) product uniquely enriched in semiconducting tubes, with (6,5) chirality being most abundant. Approximately 95% of the CNTs in SG65i are semiconducting, with approximately 41% of those tubes being (6,5) chirality.

Application

Suitable for use in printed semiconductors, photovoltaic devices, sensors, medical research, etc.

Preparation Note

CoMoCAT Catalytic Chemical Vapor Deposition (CVD) Method

Legal Information

CHASM is a trademark of Chasm Advanced Materials
CoMoCAT is a trademark of Chasm Advanced Materials
Signis is a registered trademark of Chasm Advanced Materials

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
704121724777901002
assay

≥95% carbon basis (≥95% as carbon nanotubes)

assay

≥90% carbon basis (≥77% as carbon nanotubes)

assay

≥90% carbon basis (≥80% as carbon nanotubes)

assay

>95% carbon basis

form

powder (freeze-dried)

form

powder (freeze-dried)

form

powder (freeze-dried)

form

-

Quality Level

100

Quality Level

200

Quality Level

100

Quality Level

100

description

G/D Ratio: ≥20 (Raman 633 nm), Median length: 1 μm

description

G/D Ratio: ≥15 (Raman 633nm), Median length: 1 μm

description

G/D Ratio: ≥15 (Raman 633 nm), Median length: 1 μm

description

-

density

1.7-1.9 g/cm3 at 25 °C (lit.)

density

1.7-1.9 g/cm3 at 25 °C (lit.)

density

1.7-1.9 g/cm3 at 25 °C (lit.)

density

~2.1 g/mL at 25 °C (lit.)

average diameter

0.78 nm

average diameter

0.83 nm

average diameter

-

average diameter

-


Still not finding the right product?

Explore all of our products under Carbon nanotube, single-walled


Storage Class

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Articles

A nanocomposite is typically defined as a mixture between a host material (e.g., polymer matrix) and nanofillers with at least one dimension of less than 100 nm.

Carbon-based Sustainable Organic Electronics (SOE) limit the use of critical elements and biodegrade at their end-of-life. This review offers insight on how structural and energy disorder in these materials influence device performance and includes evaluations of various transport models and their limitations.

Single-Walled Carbon Nanotubes synthesized by the Super-Growth Method & their properties & applications, including dispersing SGCNTs, SGCNT-polymer composites & SGCNT-metal composites are discussed.

View All Articles

Gabriele Selvaggio et al.
Nature communications, 11(1), 1495-1495 (2020-03-22)
Imaging of complex (biological) samples in the near-infrared (NIR) is beneficial due to reduced light scattering, absorption, phototoxicity, and autofluorescence. However, there are few NIR fluorescent materials known and suitable for biomedical applications. Here we exfoliate the layered pigment CaCuSi4O10
Anton V Naumov et al.
Nano letters, 9(9), 3203-3208 (2009-07-31)
A new method was used to measure the fraction of semiconducting nanotubes in various as-grown or processed single-walled carbon nanotube (SWCNT) samples. SWCNT number densities were compared in images from near-IR photoluminescence (semiconducting species) and AFM (all species) to compute
Tsukasa Takeuchi et al.
Bioconjugate chemistry, 30(5), 1323-1330 (2019-03-09)
Single-walled carbon nanotubes (SWCNTs) show strong fluorescence in the 1000-1700 nm second near-infrared (NIR-II) wavelength range and are considered promising candidates for angiographic imaging probes. Oxygen-doped SWCNTs coated with phospholipid-polyethylene glycol (o-SWCNT-PEG) show exceptional potential, as they emit fluorescence at



Global Trade Item Number

SKUGTIN
773735-250MG04061832930954
773735-1G04061832930947

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters