Skip to Content
MilliporeSigma

Skip To

246816

1,6-Hexanediol diacrylate

technical grade, 80%

Synonym(s):

Hexamethylene glycol diacrylate, Hexane-1,6-diyl diacrylate, HDODA

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice
100 g

Available to ship TODAYfromMILWAUKEE

$57.20
500 g

Available to ship TODAYfromMILWAUKEE

$134.00

About This Item

Linear Formula:
[H2C=CHCO2(CH2)3-]2
CAS Number:
Molecular Weight:
226.27
NACRES:
NA.23
PubChem Substance ID:
UNSPSC Code:
12162002
EC Number:
235-921-9
MDL number:

$57.20


Available to ship TODAYDetails


Request a Bulk Order
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


grade

technical grade

Quality Segment

vapor density

>1 (vs air)

vapor pressure

<0.01 mmHg ( 20 °C)

assay

80%

form

liquid

contains

100 ppm monomethyl ether hydroquinone as inhibitor

refractive index

n20/D 1.456 (lit.)

density

1.01 g/mL at 25 °C (lit.)

SMILES string

C=CC(=O)OCCCCCCOC(=O)C=C

InChI

1S/C12H18O4/c1-3-11(13)15-9-7-5-6-8-10-16-12(14)4-2/h3-4H,1-2,5-10H2

InChI key

FIHBHSQYSYVZQE-UHFFFAOYSA-N

General description

1,6-Hexanediol diacrylate is a di-functional monomer commonly used in the polymer industry for producing various types of polymers. It is a viscous liquid, that is often used as a crosslinking agent in radical polymerization reactions. Additionally, it also finds use in various fields such as coatings, adhesives, 3D printing, medical devices, and textiles due to its excellent polymerization properties and versatility.

Application

1,6-Hexanediol diacrylate can be used as:
  • A monomer for the synthesis of poly(1,6-hexanediol diacrylate) (PHDA)-based polymer microspheres and bifunctional microcapsules. The resulting PHDA-based polymer embedded with TiO2 nanoparticles finds uses in various potential applications in fields such as sensing, drug delivery, and photonics.
  • A sensitizer in the UV-curable inks commonly used in the printing industry.
  • A cross-linking agent in conjunction with a photocatalytic system to modify cellulose material. The resulting crosslinked cellulose material finds uses in various potential applications such as paper manufacturing, textiles, and biomedical devices.
  • A monomer in the synthesis of polyurethane acrylate (PUA) which is used to produce polymer electrolytes for use in lithium batteries.
1,6-Hexanedioldiacrylate can be used as a starting material to synthesize:
  • A resin (copolymer of 1,6-hexanediol diacrylate and styrene) by suspension polymerization, which is applicable in the preparation of hydrophobic peptide sequences.
  • Monodispersed poly(HDDA)/TiO2 microspheres, applicable in the degradation of methylene blue.


pictograms

Exclamation markEnvironment

signalword

Warning

Hazard Classifications

Aquatic Acute 1 - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1

Storage Class

10 - Combustible liquids

wgk

WGK 2

flash_point_f

235.4 °F - closed cup

flash_point_c

113 °C - closed cup

ppe

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Ebrahim Behroodi et al.
Scientific reports, 9(1), 19692-19692 (2019-12-25)
Projection microstereolithography (PµSL) is a promising additive manufacturing technique due to its low cost, accuracy, speed, and also the diversity of the materials that it can use. Recently it has shown great potentials in various applications such as microfluidics, tissue
B Thonemann et al.
Dental materials : official publication of the Academy of Dental Materials, 18(4), 318-323 (2002-05-07)
The use of adequate target cells for cytotoxicity testing of dental restorative materials has often been experimentally assessed with respect to the clinical relevance of the test results. In the present study, the responses in primary bovine dental papilla-derived cells
Terry W J Steele et al.
European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V, 80(1), 14-24 (2011-09-20)
Hexanediol diacrylate cross-linked oligoethylenimine (OEI-HD) is a non-viral polymeric vector designed to deliver siRNA. To achieve safe and effective in vivo siRNA delivery using this vector, the polyplex must have sufficient colloidal stability if administered intravenously or nebulized for delivery



Global Trade Item Number

SKUGTIN
246816-100G04061825882444
246816-500G04061825882468

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. Bonjour, le monomère se vend t-il sous forme liquide ? Je voudrais aussi savoir ce que signifie "technical grade 80%. MERCI

    1 answer
    1. Yes, this product is sold in a liquid format as mentioned in the "Properties" section and on "Product Specification" sheet. Technical grade chemicals contain a small amount of other chemicals and are suitable for use only for commercial or industrial purposes and not for food or drug-related applications. The 80% refers to the item containing 80mL of the product 1,6-Hexanediol diacrylate out of the total volume of 100ml.

      Helpful?

Reviews

No rating value

Active Filters