跳轉至內容
Merck
  • The role of methanol addition to water samples in reducing analyte adsorption and matrix effects in liquid chromatography-tandem mass spectrometry.

The role of methanol addition to water samples in reducing analyte adsorption and matrix effects in liquid chromatography-tandem mass spectrometry.

Journal of chromatography. A (2015-03-10)
Wei Li, Yucan Liu, Jinming Duan, Christopher P Saint, Dennis Mulcahy
摘要

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis coupled simply with water filtering before injection has proven to be a simple, economic and time-saving method for analyzing trace-level organic pollutants in aqueous environments. However, the linearity, precision and detection limits of such methods for late-eluting analytes were found to be much poorer than for early-eluting ones due to adsorption of the analytes in the operating system, such as sample vial, flow path and sample loop, creating problems in quantitative analysis. Addition of methanol (MeOH) into water samples as a modifier was shown to be effective in alleviating or even eliminating the negative effect on signal intensity for the late-eluting analytes and at the same time being able to reduce certain matrix effects for real water samples. Based on the maximum detection signal intensity obtained on desorption of the analytes with MeOH addition, the ratio of the detection signal intensity without addition of MeOH to the maximum intensity can be used to evaluate the effectiveness of methanol addition. Accordingly, the values of <50%, 50-80%, 80-120% could be used to indicate strong, medium and no effects, respectively. Based on this concept, an external matrix-matched calibration method with the addition of MeOH has been successfully established for analyzing fifteen pesticides with diverse physico-chemical properties in surface and groundwater with good linearity (r(2): 0.9929-0.9996), precision (intra-day relative standard deviation (RSD): 1.4-10.7%, inter-day RSD: 1.5-9.4%), accuracy (76.9-126.7%) and low limits of detection (0.003-0.028μg/L).

材料
產品編號
品牌
產品描述

Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
甲醇, BioReagent, ≥99.93%
Sigma-Aldrich
甲醇, Absolute - Acetone free
Sigma-Aldrich
甲醇, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
聚四氟乙烯, powder (free-flowing), 1 μm particle size
USP
木精, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
聚四氟乙烯, powder, >40 μm particle size
Sigma-Aldrich
敌草隆, ≥98%
Sigma-Aldrich
甲醇, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Supelco
甲醇, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
聚四氟乙烯, powder, 200 μm particle size
Supelco
阿特拉津, PESTANAL®, analytical standard
Supelco
甲醇, analytical standard
Sigma-Aldrich
聚四氟乙烯, beads
Supelco
马拉硫磷, PESTANAL®, analytical standard
Sigma-Aldrich
聚四氟乙烯, powder, 35 μm particle size
Sigma-Aldrich
聚四氟乙烯, powder (free-flowing), ≤12 μm particle size
Sigma-Aldrich
甲醇, NMR reference standard
Sigma-Aldrich
聚四氟乙烯, powder, ≥350 μm particle size
Supelco
二嗪磷, PESTANAL®, analytical standard
Sigma-Aldrich
1-萘基-N-甲基氨基甲酸酯, 97%
Supelco
甲萘威, PESTANAL®, analytical standard