跳轉至內容
Merck
全部照片(1)

重要文件

48707

Supelco

多氯联苯 1254溶液 溶液

certified reference material, 200 μg/mL in methanol

登入查看組織和合約定價


About This Item

CAS號碼:
分類程式碼代碼:
12000000

等級

certified reference material
TraceCERT®

agency

EPA 505,508,8082
MISA (Canada) Group 27

產品線

TraceCERT®

CofA

current certificate can be downloaded

特點

standard type calibration

包裝

ampule of 1 mL

濃度

200 μg/mL in methanol

技術

HPLC: suitable
gas chromatography (GC): suitable

應用

environmental

形式

multi-component solution

儲存溫度

2-30°C

InChI

1S/C12H5Cl5/c13-8-3-1-2-6(10(8)15)7-4-5-9(14)12(17)11(7)16/h1-5H

InChI 密鑰

AUGNBQPSMWGAJE-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

應用

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

其他說明

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

法律資訊

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Aquatic Chronic 2 - Flam. Liq. 2 - STOT RE 2 - STOT SE 1

標靶器官

Eyes

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 3

閃點(°F)

51.8 °F - closed cup - Solvent

閃點(°C)

11 °C - closed cup - Solvent

個人防護裝備

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Jing An et al.
Toxicology, 295(1-3), 8-14 (2012-03-13)
Polychlorinated biphenyls (PCBs) are still prevalent in the environment despite the fact that they have been banned in many countries for several decades. Recent epidemiologic studies have demonstrated a link between PCBs exposure and pathological alterations of bone tissues. The
L A Martin et al.
Drug metabolism and disposition: the biological fate of chemicals, 40(3), 588-595 (2011-12-22)
Polychlorinated biphenyl (PCB) congeners differentially reduce serum thyroxine (T(4)) in rats, but little is known about their ability to affect biliary excretion of T(4). Thus, male Sprague-Dawley rats were orally administered Aroclor-1254, Aroclor-1242 (32 mg/kg per day), PCB-95, PCB-99, PCB-118
Jiali Cai et al.
Toxicology, 287(1-3), 21-28 (2011-06-15)
The testicular toxicity of polychlorinated biphenyls (PCBs) has been extensively studied. However, the detailed mechanism is still obscure. In the present study, male C57 mice were treated with different doses of Aroclor 1254 (a commercial PCB mixture) once every 3
Te-Hao Chen et al.
Ecotoxicology and environmental safety, 75(1), 207-212 (2011-09-23)
Polychlorinated biphenyls (PCBs) are a group of widespread contaminants, and accumulation of PCBs has been observed in corals in the field. However, the toxic effects of PCBs on corals have not been investigated. In this study, we tested short and
Kyung Ho Kim et al.
Neurotoxicology, 32(6), 981-985 (2011-05-17)
Ortho-substituted polychlorinated biphenyls (PCBs) are a concern to human developmental health. Rat dams were exposed to an environmentally relevant mixture of PCBs, Aroclor 1254, or pure congener PCB 95 (6 mg/kg/day) during the perinatal period (GD 5 through PD 21).

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務