推薦產品
等級
certified reference material
TraceCERT®
產品線
TraceCERT®
CofA
current certificate can be downloaded
包裝
ampule of 1 mL
濃度
1000 μg/mL in methanol
技術
HPLC: suitable
gas chromatography (GC): suitable
應用
cleaning products
cosmetics
environmental
food and beverages
personal care
格式
single component solution
儲存溫度
2-8°C
InChI
1S/C2H2Cl2/c1-2(3)4/h1H2
InChI 密鑰
LGXVIGDEPROXKC-UHFFFAOYSA-N
尋找類似的產品? 前往 產品比較指南
一般說明
这种物质被列入EU第10/2011号法规中用于与食品接触的塑料的正面清单。10/2011号清单所列全部化合物的标准物质见此
1,1-二氯乙烯是一种反应性强且易燃的液体,在与氯乙烯或丙烯腈生产共聚物过程中可起到中间体的作用。
1,1-二氯乙烯是一种反应性强且易燃的液体,在与氯乙烯或丙烯腈生产共聚物过程中可起到中间体的作用。
應用
有关合适的仪器技术的更多信息,请参阅产品′的检验报告。想要获得更多支持,请联系技术服务部。
其他說明
该认证标准物质(CRM)根据ISO 17034 和 ISO/IEC 17025进行生产和认证。有关此CRM使用的所有信息均可在检验报告上找到。
法律資訊
TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany
訊號詞
Danger
危險分類
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
標靶器官
Eyes,Central nervous system
儲存類別代碼
3 - Flammable liquids
水污染物質分類(WGK)
WGK 2
閃點(°F)
51.8 °F - closed cup
閃點(°C)
11 °C - closed cup
個人防護裝備
Eyeshields, Faceshields, Gloves
客戶也查看了
Biohazards of Drinking Water Treatment (1988)
Renal tumorigenicity of 1, 1-dichloroethene in mice: the role of male-specific expression of cytochrome P450 2E1 in the renal bioactivation of 1, 1-dichloroethene
Toxicology and Applied Pharmacology, 130(1), 48-56 (1995)
Clinics in occupational and environmental medicine, 4(3), 413-421 (2004-08-25)
This article presents the current knowledge and clinical applications of the use of biomarkers of exposure to the halogenated solvents 1,1,1 trichloroethane (methylchloroform), trichloroethylene, tetrachloroethylene (perchloroethylene), and 1,1 dichloroethylene (vinylidene chloride). Although some studies have shown that protein and DNA
Shokuhin eiseigaku zasshi. Journal of the Food Hygienic Society of Japan, 46(1), 8-12 (2005-05-11)
A headspace GC/MS analysis method for the simultaneous determination of residual vinyl chloride (VC) and vinylidene chloride (VDC) in polyvinyl chloride (PVC) and polyvinylidene chloride (PVDC) products was developed. A test sample was swelled overnight with N,N-dimethylacetamide in a sealed
Clinics in occupational and environmental medicine, 4(3), 423-443 (2004-08-25)
Vapor intrusion must be recognized appropriately as a separate pathway of contamination. Although many issues resemble those of other forms of contamination (particularly its entryway, which is similar to that of radon seepage), vapor intrusion stands apart as a unique
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務