推薦產品
材料
fused silica
品質等級
agency
meets requirements for USP G27 and G36
參數
-60-300 °C temperature (isothermal or programmed)
β值
16
df
5.00 μm
技術
gas chromatography (GC): suitable
長度 × 內徑
50 m × 0.32 mm
基質活性組
Bonded; poly(5% diphenyl/95% dimethyl siloxane) phase
柱類型
capillary non-polar
尋找類似的產品? 前往 產品比較指南
一般說明
应用:这种非极性通用色谱柱主要使得组份按照沸点高低顺序洗脱,选择性略有提高,特别适用于芳香族化合物。
USP 代码:本色谱柱符合 USP G27 和 G36 要求。
相:
USP 代码:本色谱柱符合 USP G27 和 G36 要求。
相:
- 结合的
- 聚(5% 二苯基/ 95% 二甲基硅氧烷)
- ≤0.32mm 内径,<2 μm:-60°C 至 320°C(等温或程序化)
- ≤0.32mm 内径,<2 μm:-60°C 至 300°C(等温或程序化)
- ≥0.53mm 内径,<2 μm:-60°C 至 300°C(等温)或 320°C(程序化)
- ≥0.53mm 内径,<2 μm:-60°C 至 260°C(等温)或 280°C(程序化)
應用
其他說明
We offer a variety of chromatography accessories including analytical syringes
法律資訊
SPB is a registered trademark of Merck KGaA, Darmstadt, Germany
Manolis Mandalakis et al.
Journal of chromatography. A, 996(1-2), 163-172 (2003-07-02)
Operation parameters of a preparative capillary gas chromatography (pcGC) system were optimized to facilitate clean and efficient harvesting of individual polycyclic aromatic hydrocarbons (PAHs) for subsequent compound-specific radiocarbon analysis. For PAHs, the recommended optimized settings of the specially-designed pcGC cooled
L J Krutz et al.
Journal of chromatography. A, 999(1-2), 103-121 (2003-07-30)
Liquid-liquid extraction or solid-phase extraction followed by gas chromatography (GC) or high-performance liquid chromatography are traditional herbicide residue determination methods for environmental samples. Solid-phase microextraction (SPME) is a solventless, fast, and sensitive alternative herbicide residue extraction method that can be
V Gajdůsková et al.
Veterinarni medicina, 37(8), 471-478 (1992-08-01)
Occurrence of individual polychlorinated biphenyl (PCB) congeners in the environment, foodstuffs and other biological materials was assessed. Analysis of specific PCB congeners (28, 52, 101, 138, 153, 180), occurring in animal raw materials and foodstuffs most frequently, has been implemented.
Development of a passive sampler to measure personal exposure to gaseous PAHs in community settings.
Zhihua Fan et al.
Environmental science & technology, 40(19), 6051-6057 (2006-10-21)
A sensitive, simple, and cost-effective passive sampling methodology was developed to quantify personal exposure to gaseous polycyclic aromatic hydrocarbons (PAHs). A Fan-Lioy passive PAH sampler (FL-PPS) is constructed from 320 sections of 1-cm long SPB-5 GC columns (0.75-mm i.d. and
J M Jurado et al.
Talanta, 106, 14-19 (2013-04-20)
4-Methylsterols and 4,4-dimethylsterols of 47 samples of subcutaneous fat from Iberian pigs reared on two different fattening systems, "Extensive" and "Intensive", have been analyzed by GC-MS and GC-FID. The lipids were extracted by melting the subcutaneous fat in a microwave
Active Filters
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務