跳轉至內容
Merck
全部照片(1)

重要文件

S8263

Sigma-Aldrich

氢氧化钠 溶液

5.0 M

登入查看組織和合約定價


About This Item

線性公式:
NaOH
CAS號碼:
分子量::
40.00
MDL號碼:
分類程式碼代碼:
12352316
PubChem物質ID:
NACRES:
NA.21
暫時無法取得訂價和供貨情況

等級

Molecular Biology
for molecular biology

agency

suitable for SM 4500 - NH3

蒸汽壓力

3 mmHg ( 37 °C)

形狀

liquid

濃度

5.0 M

pH值

14

密度

1.327 g/cm3 at 25 °C

儲存溫度

room temp

SMILES 字串

[OH-].[Na+]

InChI

1S/Na.H2O/h;1H2/q+1;/p-1

InChI 密鑰

HEMHJVSKTPXQMS-UHFFFAOYSA-M

尋找類似的產品? 前往 產品比較指南

應用

氢氧化钠溶液可用于:
  • 在雷尼镍催化的肟、亚胺和腙还原反应中作为碱使用。[1]
  • 制备反式-1,2-环己二胺四乙酸标准液,以便合成铁螯合物。[2]
  • 合成放射性标记喹啉基类似物,以便进行α-突触核蛋白结合分析。[3]

象形圖

Corrosion

訊號詞

Danger

危險聲明

危險分類

Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A

儲存類別代碼

8B - Non-combustible corrosive hazardous materials

水污染物質分類(WGK)

WGK 1

閃點(°F)

Not applicable

閃點(°C)

Not applicable


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Design, synthesis, and in vitro evaluation of quinolinyl analogues for α-synuclein aggregation
Yue X, et al.
Bioorganic & medicinal chemistry letters, 28, 1011-1019 (2018)
Convenient method for reduction of CN double bonds in oximes, imines, and hydrazones using sodium borohydride-Raney Ni system
Yang Y, et al.
Synthetic Communications, 42, 2540-2554 (2012)
Solubility of dimethyldisulfide (DMDS) in aqueous solutions of Fe (III) complexes of trans-1, 2-cyclohexanediaminetetraacetic acid (CDTA) using the static headspace method
Iliuta MC and Larachi F
Fluid Phase Equilibria, 233, 184-189 (2005)
Xi-Ping Huang et al.
Nature, 527(7579), 477-483 (2015-11-10)
At least 120 non-olfactory G-protein-coupled receptors in the human genome are 'orphans' for which endogenous ligands are unknown, and many have no selective ligands, hindering the determination of their biological functions and clinical relevance. Among these is GPR68, a proton
Nicole von Burg et al.
Proceedings of the National Academy of Sciences of the United States of America, 111(35), 12835-12840 (2014-08-20)
Group 3 innate lymphoid cells (ILC3s) have emerged as important cellular players in tissue repair and innate immunity. Whether these cells meaningfully regulate adaptive immune responses upon activation has yet to be explored. Here we show that upon IL-1β stimulation

相關內容

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

Questions

1–2 of 2 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務