跳轉至內容
Merck
全部照片(1)

重要文件

00676

Sigma-Aldrich

三辛基氧化膦

for extraction analysis, ≥98.5%

同義詞:

TOPO®, (Oct)3PO

登入查看組織和合約定價


About This Item

線性公式:
[CH3(CH2)7]3PO
CAS號碼:
分子量::
386.63
Beilstein:
1796648
EC號碼:
MDL號碼:
分類程式碼代碼:
12352001
PubChem物質ID:
NACRES:
NA.22
暫時無法取得訂價和供貨情況

品質等級

化驗

≥98.5% (GC)
≥98.5%

反應適用性

reaction type: Buchwald-Hartwig Cross Coupling Reaction
reaction type: Heck Reaction
reaction type: Hiyama Coupling
reaction type: Negishi Coupling
reaction type: Sonogashira Coupling
reaction type: Stille Coupling
reaction type: Suzuki-Miyaura Coupling
reagent type: ligand

雜質

≤0.2% free acid (as H3PO4)
≤0.5% water

bp

201-202 °C/2 mmHg (lit.)

mp

50-52 °C (lit.)
52-55 °C

正離子痕跡

Ca: ≤10 mg/kg
Cd: ≤5 mg/kg
Co: ≤5 mg/kg
Cr: ≤5 mg/kg
Cu: ≤5 mg/kg
Fe: ≤5 mg/kg
K: ≤10 mg/kg
Mg: ≤5 mg/kg
Mn: ≤5 mg/kg
Na: ≤10 mg/kg
Ni: ≤5 mg/kg
Pb: ≤5 mg/kg
Zn: ≤5 mg/kg

官能基

phosphine oxide

SMILES 字串

CCCCCCCCP(=O)(CCCCCCCC)CCCCCCCC

InChI

1S/C24H51OP/c1-4-7-10-13-16-19-22-26(25,23-20-17-14-11-8-5-2)24-21-18-15-12-9-6-3/h4-24H2,1-3H3

InChI 密鑰

ZMBHCYHQLYEYDV-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

應用

Catalyst in:
  • Preparation of tetradentate planar-chiral hydroxy-substituted ferrocenecarboxaldimine Schiff base ligands[1]
  • Reactions of allyl esters with hydrosilanes[2]
  • Asymmetric cyanosilylation of aldehydes[3]
  • Preparation of chlorothiol formates from thiols and phosgene[4]

法律資訊

TOPO is a registered trademark of Life Technologies

象形圖

Corrosion

訊號詞

Danger

危險聲明

危險分類

Aquatic Chronic 3 - Eye Dam. 1 - Skin Irrit. 2

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

446.0 °F - closed cup

閃點(°C)

230 °C - closed cup

個人防護裝備

dust mask type N95 (US), Eyeshields, Gloves


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Wettling, T.; et al.
Ger. Offen., 1993-1993 null
Belyakova, Z. V.; et al
Russ. J. Gen. Chem., 80, 728-728 (2010)
Niemeyer, J.; et al.
European Journal of Inorganic Chemistry, 680-680 (2010)
Zeng, Z.; et al.
European Journal of Organic Chemistry, 1615-1615 (2008)
Sanjeev Kumar Mahto et al.
Toxicology in vitro : an international journal published in association with BIBRA, 24(4), 1070-1077 (2010-04-07)
With the widespread use of quantum dots (QDs), the likelihood of exposure to QDs has been assumed to have increased substantially. Recently, QDs have been employed in numerous biological and medical applications. However, there is a lack of toxicological data

Questions

  1. What are the solvents that can be used to extract magnesium and calcium from Manganese Sulfate in a liquid-liquid extraction application?

    1 answer
    1. The following solvents can be used to extract magnesium and calcium from Manganese Sulfate in a liquid-liquid extraction application:
      DEHPA - 47995-U, p-Cymene - C121452-4L, Aliquat 336 (Methyltrialkylammonium chloride) - 8180790250, and Versatic Acid 10.

      Helpful?

Reviews

No rating value

Active Filters

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務