Progard® TS2 Pretreatment Pack is not classified in Europe as a hazardous substance in regards to the substance definition in Article 3 of the Regulation (EC) 1907/2006 of 18 December 2006 concerning the Registration, Evaluation, Authorization and Restriction of Chemical (REACH) and in regards to the hazardous substance and mixtures classification criteria from the Annex I of the Regulation (EC) 1272/2008 of 16 December 2008 on classification, labeling and packaging of substance and mixtures.
Therefore, this Purification Cartridge do not require in Europe any Safety Data Sheet (SDS) to be in accordance with the Regulation (EC) 1907/2006 and the Regulation (EC) 1272/2008.
Progard® TS2 Pretreatment Pack do not require a Safety Data Sheet (SDS) under the Occupational Health and Safety Administration Standard entitled “Hazard Communication” 29 CFR 1910.1200 for the United States of America.
Progard® TS2 Pretreatment Pack do not meet the criteria of a W.H.M.I.S. classification of a controlled product. As a result, a W.H.M.I.S. Material Safety Data Sheet is not required in Canada for this product.
Disposable of wastes should be in accordance with applicable regional, national, and local laws and regulations.
推薦產品
材料
EPDM rubber
cartridge (activated carbon)
cartridge
polypropylene
品質等級
特點
Optimal protection of Reverse Osmosis (RO) membrane, optimized system lifetime and performance. Removes of large particles and free chlorine from feed water with a silt density index (SDI) up to 12.
包裝
pkg of 1 unit
高度
39.5 cm (15.5 in.)
相容性
for use with AFS®
for use with Elix® Advantage
for use with Elix® Essential UV
for use with Elix® Essential
for use with Elix® Reference
for use with Milli-Q® Integral
for use with RiOs™ Essential
運輸包裝
ambient
尋找類似的產品? 前往 產品比較指南
一般說明
應用
特點和優勢
- 保护反渗透(RO)膜免受矿物结垢、有机物结垢和氯氧化的影响。
- 聚磷酸盐防止结垢。
- 载银活性炭减少游离氯并防止细菌繁殖。
- 深度过滤去除了颗粒和胶体。
- e-Sure RFID标签确保完全可追溯性,并可随时查看包装参数。
- 为确保最有效果,建议每6个月更换。
法律資訊
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。
客戶也查看了
-
Come smaltire i blocchi già utilizzati?
1 answer-
Helpful?
-
-
What are the storage conditions for this product?
1 answer-
Recommended storage conditions: temperatures from 5 to 30°C; humidity between 10 and 80%. The original sealed bag (if provided) must be kept intact before the first use to protect the purification element from foreign matter.
Helpful?
-
-
How are consumables changed?
1 answer-
To help you to change your system's consumables, several video tutorials are available on our YouTube channel: https://youtube.com/playlist?list=PL2TUriaAaEA_IXDCnPbDk6OmrwptjwOHD. For high-flow systems, please keep in mind that all consumable changes must be approved by a 3-digit code that only the person in charge of the system knows.
Helpful?
-
-
How can I know which consumables can be used with my system?
1 answer-
To know which consumables can be used on your system, you can see in the user manual of your system or see all the consumables for each system listed on https://www.sigmaaldrich.com/products/water-purification/milli-q-consumables.
Helpful?
-
-
What steps are you taking towards improved sustainability?
1 answer-
Sustainability is at the heart of our innovations. From reducing water and energy consumption, to minimizing plastic and chemical waste, our dedicated water system engineers are constantly working on new ways to reduce the ecological footprint of our products to better support the sustainability goals we're all striving towards. For more information, we invite you to review the following brochure and infographic which highlight our efforts and achievements: https://www.sigmaaldrich.com/life-science/milliq#sus. Do not hesitate to contact your local representative or sales contact (https://www.sigmaaldrich.com/collections/offices) for further information.
Helpful?
-
-
Can I arrange to have my consumables automatically ordered and delivered once a year?
1 answer-
It's possible to place only one consumable order per year with a specific contract called "Consumable Supply Agreement (CSA)" (https://www.sigmaaldrich.com/US/en/products/water-purification/milli-q-consumables#csa). For further information, contact your local representative or sales contact (https://www.sigmaaldrich.com/US/en/collections/offices).
Helpful?
-
-
Can consumables be opened and refilled?
1 answer-
Unfortunately, this is not possible because of safety issues and the need to guarantee the quality of consumables and their interior purification components. Our consumables are manufactured in an ISO 9001-certified facility France in agreement with high quality standards.
Helpful?
-
-
What is the consumables delivery time?
1 answer-
Refer to the consumable's Product page for a first estimation of its expected delivery time and contact customer service for more information.
Helpful?
-
-
How frequently do the various consumables need to be changed?
1 answer-
The frequency that consumables must be changed depends on the system's usage (treated water volume) and on the consumables themselves (time of usage). In order to ensure the quality of water and your results, the consumables should be replaced when the system alerts you.
Helpful?
-
-
Where can I find data sheets, Certificates of Origin, Certificates of Analysis, and Certificates of Quality?
1 answer-
Documents and certificates are available in the "Documentation" section on this page. Do not hesitate to contact us if you require further information.
Helpful?
-
Active Filters
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務