跳轉至內容
Merck

KHVEG3TTT1H

Millipore

Millipore Express® SHR High Area with prefilter 0.5/0.1µm, Opticap® XLT 30 Capsule

Fittings 1-1/2 in. TC, Gamma Compatible

登入查看組織和合約定價


About This Item

分類程式碼代碼:
23151806
暫時無法取得訂價和供貨情況

產品名稱

Millipore Express® SHRP High Area, Opticap® XLT Capsule, Opticap® XLT 30, cartridge nominal length 30 in. (75 cm), filter diam. 4.2 in. (10.7 cm)

材料

polyester support
polypropylene housing
silicone seal
vent cap (gamma stable polypropylene)

品質等級

法律遵循

meets FDA 21 CFR 177-182 (all component materials)

無菌

non-sterile

滅菌相容性

gamma compatible

產品線

Opticap® XLT 30

特點

hydrophilic

製造商/商標名

Millipore Express®

參數

≤162.6 mL/min air diffusion at 3.45 bar (50 psig) (in water)
1 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet pressure
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psig max. inlet pressure

技術

sterile filtration: suitable

長度

34.3 in.

寬度

7.8 in.

柱標稱長度

30 in. (75 cm)

過濾器直徑

4.2 in. (10.7 cm)

過濾器尺寸

30 in.

過濾面積

3.0 m2

雜質

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)

基質

Millipore Express® SHR ((w/Prefilter High Area))

pore size

0.5/0.1 μm pore size

起泡點

≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water

接頭

1/4 in. drain/vent connection ( hose barb with double o-ring seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)

應用

filtration

尋找類似的產品? 前往 產品比較指南

一般說明

Device Configuration: Capsule

特點和優勢

T-line/Gauge Port: T-line

包裝

Double Easy-Open bag

準備報告

Sterilization Method: Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min at 123 °C; not in-line steam sterilizable

This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

分析報告

Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L

TOC/Conductivity: After sterilization and a controlled water flush of 60 L, samples exhibited <500 ppb TOC per USP 643 and <1.3 μS/cm per USP 645 at 25 °C.

Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.

其他說明

Directions for Use
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
  • Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

法律資訊

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

什麼是Emprove® 套裝?

Emprove® 計劃是一個為我們的篩選器和單次用元件、製藥原料和起始材料提供全面徹底記錄的系統。

Material Qualification Dossier

免費—登入下載

Material Qualification Dossier

免費—登入下載

Operational Excellence Dossier

可透過訂閱或付費取得

了解更多效益 Emprove® 計畫訂閱可提供
為什麼沒有這些文件?
Emprove® 檔案包含旨在支持藥品生產商的註冊過程和風險評估活動的訊息,並包含機密資訊。如果您想存取,請聯絡我們

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Questions

Reviews

No rating value

Active Filters

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務