HKI1MAG-99K
MILLIPLEX® 人肾损伤磁珠板1 - 毒性多重检测
The analytes available for this multiplex kit are: Calbindin, Collagen IV, Fatty Acid Binding Protein 1 (FABP1), GSTα, IP-10, Kidney Injury Molecule-1 (KIM-1), Renin, TFF-3, TIMP-1.
About This Item
推薦產品
品質等級
物種活性
human
製造商/商標名
Milliplex®
assay range
accuracy: 73-117%
sensitivity: 0.010-6.473 ng/mL
(MinDC = 2SD)
standard curve range: 0.005-5 ng/mL
(IP-10)
standard curve range: 0.02-25 ng/mL
(Renin)
standard curve range: 0.05-50 ng/mL
(GSTα)
standard curve range: 0.05-50 ng/mL
(KIM-1)
standard curve range: 0.10-100 ng/mL
(TIMP-1)
standard curve range: 0.20-200 ng/mL
(Calbindin)
standard curve range: 0.34-350 ng/mL
(Collagen IV)
standard curve range: 0.49-500 ng/mL
(TFF-3)
standard curve range: 5.86-6,000 ng/mL
(FABP1)
inter-assay cv: <15%
intra-assay cv: <10%
技術
multiplexing: suitable
檢測方法
fluorometric (Luminex xMAP)
運輸包裝
wet ice
一般說明
MILLIPLEX®产品组合提供了有价值的研究分析方法,可以使用Luminex® xMAP®仪器平台研究人类尿液样品中肾脏损伤的多种生物标志物。可用于该多重试剂盒的分析物包括:钙结合蛋白、胶原IV、脂肪酸结合蛋白1(FABP1)、GSTα、IP-10、肾损伤分子-1(KIM-1)、肾素、TFF-3、TIMP-1。
面板类型:毒性
特異性
对于面板中的一种分析物和任何其他分析物,抗体之间没有或有可以忽略不计的交叉反应性。
應用
- 分析物:钙结合蛋白、IV型胶原、FABP1、GSTα、IP-10、KIM-1、肾素、TFF-3、TIMP-1
- 推荐的样品稀释类型:尿
- 推荐的样品稀释度:1:2试剂盒检测缓冲液客户需要确定其样品的最佳稀释因子。我们的建议基于正常受试者的尿液样品。
- 分析运行时间:过夜
- 研究类别:毒性
特點和優勢
其他說明
法律資訊
免責聲明
訊號詞
Danger
危險分類
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
標靶器官
Respiratory Tract
儲存類別代碼
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。
相關內容
Novel kidney toxicity biomarkers expand options for acute nephrotoxicity detection. Multiplex assays measure multiple renal damage biomarkers in small sample volumes, minimizing time and costs. See how MILLIPLEX® multiplex kidney toxicity assays detected vancomycin-induced subacute nephrotoxicity in rat models.
Multiplex toxicity assays enable researchers to simultaneously measure multiple toxicity biomarkers of various organs to gain a better understanding of toxicity. Explore how MILLIPLEX® multiplex toxicity assays are advancing research on liver injury, kidney toxicity, genotoxicity, and more.
發現以 Luminex® xMAP® 多重檢測技術為基礎的 MILLIPLEX® 多重檢測的優點,可提供一致、高品質的結果,並瞭解這些多重生物標誌物 Luminex® 檢測如何用於推動研究。
Discover the benefits of MILLIPLEX® multiplex assays, based on Luminex® xMAP® multiplex assay technology, that provide consistent, high-quality results and see how these multiplex biomarker Luminex® assays are being used to advance research.
Active Filters
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務