跳轉至內容
Merck
全部照片(1)

文件

03-0196-00

Millipore

SMC® Human Total α-synuclein High Sensitivity Immunoassay Kit

Uses 100 µL per well of 1:200 diluted serum or plasma samples, or 1:10 diluted cerebrospinal fluid (CSF) samples.

同義詞:

Human α-synuclein, α-synuclein, Human total-α-synuclein, a-synuclein, total-a-synuclein

登入查看組織和合約定價


About This Item

分類程式碼代碼:
12161503
NACRES:
NA.84

物種活性

canine, rat, feline, mouse

製造商/商標名

SMC®

assay range

sensitivity: 1.95  pg/mL
(LLOQ of Total α-synuclein)

inter-assay cv: 14%
intra-assay cv: 9%
(five normal plasma samples run in triplicate by 3 different operators on 3 different days)

技術

single molecule counting: suitable

一般說明

The SMC® Human Total-α-Synuclein High Sensitivity Immunoassay Kit contains all reagents required to perform the assay. This assay takes advantage of a standard immunoassay workflow configured in a standard plate format. Assay protocols are similar to existing sandwich ELISA methods with two key differences:
1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification.
2) The Erenna and SMCxPRO® immunoassay systems detect analytes using Single Molecule Counting (SMC®) technology.

特異性

Species Reactivity Note

Specificity to the following species samples were tested with the following results:
Monkey – 100%
Cat – 100%
Rat – 100%
Mouse – 100%
Beagle – 100%

Cross Reactivity

Cross-reactivity to the following analytes were tested with the following results:
Tau – 0%UCHL1 – 0%
β-synuclein – 0%
γ-synuclein – 0%

Accuracy

CSF Recovery: 5 CSF samples spiked with average recovery of 96% and a range of 90-102%
Serum Recovery: 4 serum samples spiked with average recovery of 96% and a range of 93-98%
Plasma Recovery: 4 plasma samples spiked with average recovery of 96% and a range of 93-97%

應用

Uses 100 µL per well of 1:200 diluted serum or plasma samples, or 1:10 diluted cerebrospinal fluid (CSF) samples.

包裝

96 well assay

成分

  • Assay Buffer
  • Total α-synuclein Coated Beads
  • Standard Diluent
  • Total α-synuclein Detection Antibody
  • Total α-synuclein Standard
  • 10X Wash Buffer
  • Buffer D
  • Elution Buffer B

其他說明

  • This new streamline kit has the following features:
  • Improved options for sample prep and incubation
  • Lyophilization protein standard for uniform shipping and storage condition
  • Increased reagent volumes to accommodate automation
  • Able to achieve assay specifications on both SMCxPRO® and Erenna.

法律資訊

SMC is a registered trademark of Singulex
SMCxPRO is a registered trademark of Merck KGaA, Darmstadt, Germany

免責聲明

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

象形圖

Skull and crossbonesHealth hazard

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B

儲存類別代碼

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

閃點(°F)

Not applicable

閃點(°C)

Not applicable


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

相關內容

Neuroscience biomarker research expands with high-sensitivity immunoassays for low-abundant biomarkers.

Explore high-sensitivity SMC® neurology immunoassays that precisely measure low levels of neurology protein analytes, such as NF-L or Tau proteins.

通过适合的免疫检测产品,探索神经免疫和神经炎症细胞因子及神经退行性疾病生物标志物。

Find immunoassays to explore neuroimmunology and neuroinflammation cytokines and neurodegenerative disease biomarkers.

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務