N-017

Supelco

去甲哌替啶标准液 溶液

100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C14H19NO2
CAS號碼:
分子量::
233.31
EC號碼:
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24

等級

certified reference material

形狀

liquid

特點

Snap-N-Spike®/Snap-N-Shoot®

包裝

ampule of 1 mL

製造商/商標名

Cerilliant®

drug control

Narcotic Licence Schedule A (Switzerland); estupefaciente (Spain); Decreto Lei 15/93: Tabela IA (Portugal)

濃度

100 μg/mL in methanol

技術

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

應用

forensics and toxicology

格式

single component solution

儲存溫度

−20°C

SMILES 字串

O=C(OCC)C1(C2=CC=CC=C2)CCNCC1

InChI

1S/C14H19NO2/c1-2-17-13(16)14(8-10-15-11-9-14)12-6-4-3-5-7-12/h3-7,15H,2,8-11H2,1H3

InChI 密鑰

QKHMFBKXTNQCTM-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

一般說明

去甲哌替啶是阿片类镇痛药哌替啶的主要有毒代谢物。 该认证Snap-N-Spike®溶液适用于通过LC-MS/MS、LC/MS 或 GC/MS法进行止痛药处方监测、临床毒理学、尿液药物测试或法医分析。哌替啶是一种具有类似吗啡作用的合成阿片类药物,可用作止痛药。

法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

標靶器官

Eyes,Central nervous system

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

49.5 °F - closed cup

閃點(°C)

9.7 °C - closed cup


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

J L Plummer et al.
Toxicology, 95(1-3), 37-44 (1995-01-06)
This study investigated behavioural effects of the toxic pethidine metabolite, norpethidine, in rats and its interactions with reserpine, apomorphine and physostigmine. Following intraperitoneal administration, brain concentrations of norpethidine reached a plateau after 20-40 min and remained elevated for 2 h.
Meperidine in patient-controlled analgesia: a near-fatal mishap.
R J Geller
Anesthesia and analgesia, 76(3), 655-657 (1993-03-01)
Thomas T Simopoulos et al.
Archives of surgery (Chicago, Ill. : 1960), 137(1), 84-88 (2002-01-31)
Intravenous patient-controlled analgesia (IV PCA) meperidine hydrochloride can be used with a reasonable margin of safety. A retrospective review was performed of 355 medical records of patients receiving IV PCA meperidine treatment. Four groups of patients were defined, based on
E Nissen et al.
Acta paediatrica (Oslo, Norway : 1992), 86(2), 201-208 (1997-02-01)
A standard dose of 100 mg of pethidine was given im to 13 healthy primiparae during labour. The aim of the study was to investigate whether developing breastfeeding behaviour in the newborn infant was associated with the dose-delivery time interval
W D Ngan Kee et al.
Anaesthesia and intensive care, 24(1), 51-55 (1996-02-01)
We evaluated a disposable device (Baxter PCA Infusor) for patient-controlled epidural analgesia (PCEA) using pethidine in twenty women after lower segment caesarean section. Efficacy, as measured by visual analogue pain scores, was comparable with historical controls from PCEA studies using