等級
certified reference material
形狀
liquid
特點
Snap-N-Spike®/Snap-N-Shoot®
包裝
ampule of 1 mL
製造商/商標名
Cerilliant®
濃度
1.0 mg/mL in acetonitrile
技術
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
應用
clinical testing
pharmaceutical (small molecule)
格式
single component solution
儲存溫度
−20°C
SMILES 字串
CC(C(O)=O)C(O)=O
InChI
1S/C4H6O4/c1-2(3(5)6)4(7)8/h2H,1H3,(H,5,6)(H,7,8)
InChI 密鑰
ZIYVHBGGAOATLY-UHFFFAOYSA-N
一般說明
甲基丙二酸是维生素B12 缺乏症和甲基丙二酸血症的指标。该经认证的加标溶液®适用于使用GC/MS或LC/MS制备临床和诊断测试中的校准品或质控品。
應用
- Organic acid analysis for metabolic profiling: Research highlighted the integration of soil microbiota and metabolome, where methylmalonic acid was part of the metabolic profiling, revealing insights into how controlled release fertilizer impacts sugarcane growth, emphasizing the compound′s role in agricultural biotechnology (Yuan et al., 2023).
- Vitamin B12 deficiency research: Methylmalonic acid was featured in research on the cellular mechanisms affecting the MAFB/NOTCH3 axis in osteosarcoma, where its levels could potentially reflect perturbations relevant to vitamin B12 deficiency, aiding in better understanding of disease progression (Zhang et al., 2024).
- Methylmalonic acid standard for mass spectrometry analysis: The analysis of soybean root systems under varying nutrient conditions included methylmalonic acid as a standard in mass spectrometry to better understand nutrient uptake mechanisms, showcasing its utility in plant physiology and biochemistry studies (Qin et al., 2023).
法律資訊
CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany
訊號詞
Danger
危險分類
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
儲存類別代碼
3 - Flammable liquids
水污染物質分類(WGK)
WGK 2
閃點(°F)
35.6 °F - closed cup
閃點(°C)
2 °C - closed cup
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。
客戶也查看了
European journal of clinical investigation, 43(3), 231-237 (2013-01-22)
There is an urgent need for proper utilization of laboratory markers to diagnose vitamin B12 deficiency that should reduce false negative cases. We worked out a diagnostic algorithm that provides a two-step detection of vitamin B12 deficiency using holotranscobalamin as
The Journal of nutrition, 143(2), 142-147 (2012-12-14)
Plasma vitamin B-12 is the most commonly used biomarker of vitamin B-12 status, but the predictive value for low vitamin B-12 status is poor. The urinary methylmalonic acid (uMMA) concentration has potential as a functional biomarker of vitamin B-12 status
The Science of the total environment, 442, 48-55 (2012-11-28)
Children are susceptible to mercury toxicity, and mercury has immunomodulatory effects. Lower folate and B-12, and higher homocysteine may represent susceptibility cofactors. A large proportion of variability in rubella immune response is attributable to environmental factors. This study aimed to
Revue medicale suisse, 8(360), 2052-2054 (2012-11-29)
Biological markers for the status of vitamins B12 and D: the importance of some analytical aspects in relation to clinical interpretation of results When vitamin B12 deficiency is expressed clinically, the diagnostic performance of total cobalamin is identical to that